Viewing the ServeRAID II controller status:
When you select View Adapter Status from the Main
Menu, a screen similar to the following appears.
Bay
Array
Bay
Array
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ch
1
Ch
2
A
A
A
A
A
A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INI
OPT
IBM ServeRAID Adapter Disk Array Mini-Configuration Utility Ver. X.XX
Status for Adapter: 1
Hdwr: ISPR-EF10h BCS-OFh ESC-00h
Unattended: Off ReadAhead: On BootCd:On
CompMode: On Clustered: Off
Boot Bk : 97115 Code Bk 97115
Rebuild Rate
: High
No. Of DDD Drv.
: 0
No. Of OFL Drv.
: 0
No. Of CRT Drv.
: 0
Cfg. Updates: 1
Flash Pgms.: 10
Bad Stripe
: None
Locked Drive
: None
Blocked Drive
: None
Locked, Bad Stripe, or Blocked Drive
Press any key to continue.
ONL
ONL
ONL
ONL
ONL
ONL
CDR
INI
The screen contains the following fields:
Unattended shows the current state of the
Unattended Mode, On or Off. (See “Changing the
RAID parameters” on page 118.)
Read Ahead shows the current state of the Read
Ahead Cache Mode, On or Off. (See “Changing the
RAID parameters” on page 118.)
BootCd shows the current state of the BootCd
function, On or Off. (See “Setting the BootCd feature”
on page 90.)
CompMode shows the BIOS compatibility mode. On
indicates 8 GB Extended; Off indicates 2 GB Limited.
Boot Bk shows the current version number of the
startable code stored in the Boot Block.
Code Bk shows the current version number of the
firmware (microcode) for the ServeRAID controller.
Rebuild Rate shows the current speed of the rebuild
process: High (default), Medium, or Low. (See
“Changing the RAID parameters” on page 118.)
No. of DDD Drv. shows the current number of
defunct drives.
No. of OFL Drv. shows the current number of offline
logical drives.
No. of CRT Drv. shows the current number of critical
logical drives.
Cfg. Updates shows the current number of times that
the configuration has been updated. When you
initialize the configuration, the Cfg. Update is reset to
zero.
Flash Pgms shows the current number of times that
the firmware EEPROM has been updated.
Locked, Bad Stripe, or Blocked Drive identifies the
logical drives that are affected, and contains the
following fields:
Netfinity 5500 - Type 8660
139
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...