(CONTINUED)
Notes
1. For systems that are part of a shared DASD
cluster, run one test at a time in looped mode.
Do not run all tests in looped mode, as this could
enable the DASD diagnostic tests.
2. If multiple error codes are displayed, diagnose
the first error code displayed.
3. If the computer hangs with a POST error, go to
the “Symptom-to-FRU index” on page 264.
4. If the computer hangs and no error is displayed,
go to “Undetermined problems” on page 291.
5. Power Supply problems, see “Symptom-to-FRU
index” on page 264.
6. Safety information, see “Safety information” on
page 308.
7. For intermittent problems, check the error log;
see, “Error logs” on page 99.
001
IS THE SYSTEM PART OF A CLUSTER?
Yes No
002
Go to Step 004.
003
Schedule maintenance with the customer. Shut down all
systems related to the cluster. Run storage test.
004
– Power-off the computer and all external devices.
– Check all cables and power cords.
– Set all display controls to the middle position.
– Power-on all external devices.
– Power-on the computer.
– Check the control panel system error LED; if on, see
“Control panel system error LED” on page 267.
– Check the error log. If an error was recorded by the
system, see “Symptom-to-FRU index” on page 264.
– Start the Diagnostic Programs. See “Running
Diagnostic programs” on page 13.
– Check for the following responses:
1. No beep.
2. Readable instructions or the Main Menu.
(Step 004 continues)
8
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...