APPENDIX A
Message
Comments
GEA1 CONFIG
– GEA1 config error.
Config service req’d.
The GEA1 configuration settings do not match those of backup configuration memory.
The system should be serviced.
GEA1 INOP- CAL
- Check GEA
rigging.
There is a problem with the GEA 1 rigging. Check the rigging.
GEA1 INOP - CNFG
- Check GEA
software and configuration.
There is a problem with the GEA 1 software configuration. Check the configuration. If
the problem persists, the system should be serviced.
GEA1 INOP - INTRL
- GEA internal
fault.
GEA 1 has an internal fault. The system should be serviced.
GEA1 INOP - SENS
- Check GEA
configuration.
There is an error in the GEA 1 configuration. Check the configuration. If the problem
persists, the system should be serviced.
GEA1 INOP - TEMP
- Check GEA
cooling arrangement.
The GEA 1 configuration module has insufficient cooling. If the problem persists, the
system should be serviced.
GEA1 INOP - VOLT
- Check GEA
voltages.
The GEA 1 voltage is low. Check GEA voltages.
GEA1 INSP RQRD
- Redundant
power supply is not present.
The GEA 1 redundant power supply is not present. Check the connection.
GEA1 MANIFEST
– GEA1 software
mismatch, communication halted.
The #1 GEA 71 has incorrect software installed. The system should be serviced.
GEO LIMITS
– AHRS1 too far North/
South, no magnetic compass.
The aircraft is outside geographical limits for approved ADAHRS operation. Heading is
flagged as invalid.
GFC MANIFEST
– GFC software
mismatch, communication halted.
Incorrect servo software is installed, or gain settings are incorrect.
GIA #[1, 2] INOP - CRNT
- Check
GIA current.
GIA1 and/or GIA2 current is low. Check GIA current.
GIA #[1, 2] INOP - SERL
- Check
GIA Serial Communication.
The GIA1 and/or GIA2 communication is inoperative. They system should be serviced.
GIA #[1, 2] INOP - VOLT
- Check
GIA voltages.
The GIA1 and/or GIA2 voltage is low. Check GIA voltages.
GIA1 CONFIG
– GIA1
audio config
error. Config service req’d.
The GIA1 have an error in the audio configuration. The system should be serviced.
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 configuration settings do not match backup configuration memory. The
system should be serviced.
GIA1 COOLING –
GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.
GIA1 COOLING –
GIA1 over
temperature.
The GIA1 temperature is too high. If problem persists, the system should be serviced.
GIA1 MANIFEST
– GIA1 software
mismatch, communication halted.
The GIA1 1 has incorrect software installed. The system should be serviced.
GIA1 SERVICE
– GIA1 needs service.
Return the unit for repair.
The GIA1 self-test has detected a problem in the unit. The system should be serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
The GIA2 have an error in the audio configuration. The system should be serviced.