set port discard
Enterasys G-Series CLI Reference 7-11
set port discard
Use
this
command
to
set
the
frame
discard
mode
on
one
or
more
ports.
Syntax
set port discard
port-string
{
tagged
|
untagged
|
both
|
none
}
Parameters
Defaults
None.
Mode
Switch
command,
read
‐
write.
Usage
The
options
are
to
discard
all
incoming
tagged
frames,
all
incoming
untagged
frames,
neither
(essentially
allow
all
traffic),
or
both
(essentially
discarding
all
traffic).
A
common
practice
is
to
discard
all
tagged
packet
on
user
ports.
Typically
an
Administrator
does
not
want
the
end
users
defining
what
VLAN
they
use
for
communication.
Example
This
example
shows
how
to
discard
all
tagged
frames
received
on
port
ge
.3.3:
G3(su)->set port discard ge.3.3 tagged
Configuring the VLAN Egress List
Purpose
To
assign
or
remove
ports
on
the
egress
list
of
a
particular
VLAN.
This
determines
which
ports
on
the
switch
will
be
eligible
to
transmit
frames
for
a
particular
VLAN.
For
example,
ports
1,
5,
7,
8
could
be
allowed
to
transmit
frames
belonging
to
VLAN
20
and
ports
7,8,
9,
10
could
be
allowed
to
transmit
frames
tagged
with
VLAN
30
(a
port
can
belong
to
multiple
VLAN
Egress
lists).
Note
that
the
Port
Egress
list
for
ports
7
and
8
would
contain
both
VLAN
20
and
30.
The
port
egress
type
for
all
ports
can
be
set
to
tagged,
forbidden,
or
untagged.
In
general,
VLANs
have
no
egress
(except
for
VLAN
1)
until
they
are
configured
by
static
administration,
or
through
dynamic
mechanisms
such
as
GVRP.
port
‐
string
Specifies
the
port(s)
for
which
to
set
frame
discard
mode.
For
a
detailed
description
of
possible
port
‐
string
values,
refer
to
“
Port
String
Syntax
Used
in
the
CLI
”
on
page 4
‐
1.
tagged
|
untagged
|
both
|
none
•
Tagged
‐
Discard
all
incoming
(received)
tagged
packets
on
the
defined
port(s).
•
Untagged
‐
Discard
all
incoming
untagged
packets.
•
Both
‐
All
traffic
will
be
discarded
(tagged
and
untagged).
•
None
‐
No
packets
will
be
discarded.
Summary of Contents for G3G170-24
Page 1: ...Enterasys G Series Ethernet Switch CLI Reference Firmware Version 1 00 xx P N 9034358 01...
Page 2: ......
Page 30: ...xxviii...
Page 100: ...set ssl 2 56 Basic Configuration...
Page 132: ...clear lldp port tx tlv 3 32 Discovery Protocol Configuration...
Page 272: ...show spantree nonforwardingreason 6 52 Spanning Tree Configuration...
Page 296: ...set garp timer 7 24 802 1Q VLAN Configuration...
Page 384: ...clear nodealias config 11 34 Logging and Network Management...
Page 438: ...Enabling Router Configuration Modes 14 4 Preparing for Router Mode...
Page 514: ...show ip pimsm staticrp 16 56 IPv4 Routing Protocol Configuration...
Page 524: ...traceroute ipv6 17 10 IPv6 Management...
Page 602: ...show ipv6 ospf virtual link 19 46 OSPFv3 Configuration...