03.30 LIMIT WORD INV
The LIMIT WORD INV Word includes faults and warnings which occur when the
output current limit of the drive is exceeded. The current limit protects the drive in
various cases, for example, in case of integrator overload, high IGBT temperature,
etc.
4380
TEMP DIF xx y
4311
THERMISTOR
bit 2
FF91
T MEAS ALM
bit 6
FF6A
UNDERLOAD
bit 1
FFFB
ZERO POS WARN
FFEF
CTRL LOC DIFF
bit 12
Bit
Name
Description
0
INTEGRAT 200
Current limit at 200% integrator overload. Temperature
model is not active.*
1
INTEGRAT 150
Current limit at 150% integrator overload. Temperature
model is not active.*
2
INT LOW FREQ
Current limit at high IGBT temperature with low output
frequency (<10 Hz). Temperature model is not active.*
3
INTG PP TEMP
Current limit at high IGBT temperature. Temperature model
is not active.*
4
PP OVER TEMP
Current limit at high IGBT temperature. Temperature model
is active.
5
PP OVERLOAD
Current limit at high IGBT junction to case temperature.
Temperature model is active.
If the IGBT junction to case temperature continues to rise in
spite of the current limitation, the PP OVERLOAD alarm or
fault occurs. See chapter
6
INV POW LIM
Current limit at inverter output power limit.
7
INV TRIP CUR
Current limit at inverter overcurrent trip limit.
8
OVERLOAD CUR
Maximum inverter overload current limit. See par.
9
CONT DC CUR
Continuous dc-current limit.
10
CONT OUT CUR
Continuous output current limit (I
cont.max
).
11 … 15
Reserved
*Not active with ACS800 Default settings.
Code
Description
Application/Fault Word Status Bit
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...