Actual signals and parameters
215
92.03
MAIN DS ACT2
Selects the address from which the Actual signal 2 is read to the Main Data
Set.
0 … 9999
Parameter index
92.04
AUX1 DS ACT3
Selects the address from which the Actual signal 3 is read to the Auxiliary Data
Set.
0 … 9999
Parameter index
92.05
AUX1 DS ACT4
Selects the address from which the Actual signal 4 is read to the Auxiliary Data
Set.
0 … 9999
Parameter index
92.06
AUX1 DS ACT5
Selects the address from which the Actual signal 5 is read to the Auxiliary Data
Set.
0 … 9999
Parameter index
92.07
AUX2 DS ACT6
Selects the address from which the Actual signal 6 is read to the Auxiliary Data
Set.
0 … 9999
Parameter index
92.08
AUX2 DS ACT7
Selects the address from which the Actual signal 7 is read to the Auxiliary Data
Set.
0 … 9999
Parameter index
92.09
AUX2 DS ACT8
Selects the address from which the Actual signal 8 is read to the Auxiliary Data
Set.
0 … 9999
Parameter index
92.10
MSW B10 PTR
Selects the address from which the
Main Status Word bit 10 is read from.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
92.11
MSW B13 PTR
Selects the address from which the
Main Status Word bit 13 is read from.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
92.12
MSW B14 PTR
Selects the address from which the
Main Status Word bit 14 is read from.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
92.13
START DS TRA
Defines the starting data set where the drive writes the Status Word, Actual
signal 1 and Actual signal 2.
2
Data set number 2 is the starting address. Can be used for Standard drives.
1
11
Data set number 11 is the starting address. Can be used for multidrives.
2
Index
Name/Selection
Description
FbEq
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...