Fault tracing
288
Fault messages generated by the drive
FAULT
CAUSE
WHAT TO DO
ACS800 TEMP
(4210)
3.05 FW 1 bit 3
Drive IGBT temperature is excessive. Fault trip
limit is 100%.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
ACS TEMP xx y
(4210)
3.05 FW 1 bit 3 and
4.01
Excessive internal temperature in inverter unit
of several parallel connected inverter modules.
xx (1...12) refers to inverter module number
and y refers to phase (U, V, W).
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
AI < MIN FUNC
(8110)
3.06 FW 2 bit 10
(programmable
Fault Function
Analogue control signal is below minimum
allowed value due to incorrect signal level or
failure in control wiring.
Check for proper analogue control signal
levels.
Check control wiring.
Check Fault Function parameters.
AP [message]
Message generated by an EVENT block in the
Adaptive Program.
Consult the documentation or author of the
Adaptive Program.
BACKUP ERROR
(FFA2)
Failure when restoring PC stored backup of
drive parameters.
Retry.
Check connections.
Check that parameters are compatible with
drive.
BC OVERHEAT
(7114)
3.17 FW 5 bit 4
Brake chopper overload
Let chopper cool down.
Check parameter settings of resistor overload
protection function (see parameter group
).
Check that braking cycle meets allowed limits.
Check that drive supply AC voltage is not
excessive.
BC SHORT CIR
(7113)
3.17 FW 5 bit 2
Short circuit in brake chopper IGBT(s)
Replace brake chopper.
Ensure brake resistor is connected and not
damaged.
BRAKE ACKN
(FF74)
3.15 FW 4 bit 3
Unexpected state of brake acknowledge signal
See parameter group
Check connection of brake acknowledgement
signal.
BRAKE SLIP FLT
(FFF3)
3.33 CraneFW bit 3
The brake slipped and the motor speed
exceeded the motor slip speed
for a
period of slip fault delay
time.
Check brakes.
BR BROKEN
(7110)
3.17 FW 5 bit 0
Brake resistor is not connected or it is
damaged.
Resistance rating of brake resistor is too high.
Check resistor and resistor connection.
Check that resistance rating meets
specifications. See appropriate drive hardware
manual.
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...