Control panel
41
How to set speed reference
Step Action
Press
Key
Display
1.
To show the status row.
1
->
1242.0 rpm I
FREQ 45.00 Hz
CURRENT 80.00 A
POWER 75.00 %
2.
To switch to local control.
(Only if the drive is not under local control, that is, there is
no L on the first row of the display.)
1 L
->
1242.0 rpm I
FREQ 45.00 Hz
CURRENT 80.00 A
POWER 75.00 %
3.
To enter the Reference Setting function.
1 L
->
[1242.0 rpm]I
FREQ 45.00 Hz
CURRENT 80.00 A
POWER 75.00 %
4.
To change the reference.
(slow change)
(fast change)
1 L
->
[1325.0 rpm]I
FREQ 45.00 Hz
CURRENT 80.00 A
POWER 75.00 %
5.
To save the reference.
(The value is stored in the permanent memory; it is
restored automatically after power switch-off.)
1 L
->
1325.0 rpm I
FREQ 45.00 Hz
CURRENT 80.00 A
POWER 75.00 %
ACT
PAR
FUNC
LOC
REM
REF
ENTER
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...