Actual signals and parameters
171
14.11
RO PTR5
Defines the source or constant for value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
-
14.12
RO PTR6
Defines the source or constant for value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
-
14.13
RO PTR7
Defines the source or constant for value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
-
14.14
RO PTR8
Defines the source or constant for value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
-
14.15
RO PTR9
Defines the source or constant for value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
-
15 ANALOGUE
OUTPUTS
Selection of the actual signals to be indicated through the analogue outputs.
Output signal processing. See section
page
15.01
AO1 PTR
Defines the source or constant for value.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter index or a constant value. See parameter
for information on
the difference.
For example, default value 001.002 (signal
) is used for actual speed.
1000 =
1 mA
15.02
INVERT AO1
Inverts the analogue output AO1 signal. The analogue signal is at the minimum
level when the indicated drive signal is at its maximum level and vice versa.
NO
Inversion off
0
YES
Inversion on
65535
15.03
MINIMUM AO1
Defines the minimum value of the analogue output signal AO1.
0 mA
Zero mA
1
4 mA
Four mA
2
15.04
FILTER AO1
Defines the filtering time constant for analogue output AO1.
0.00 … 10.00 s
Filter time constant
Note:
Even if you select 0 s as the minimum value, the signal is still filtered
with a time constant of 10 ms due to the signal interface hardware. This cannot
be changed with any parameters.
0 … 1000
Index
Name/Selection
Description
FbEq
63
%
100
T
t
Filtered signal
Unfiltered signal
O = I
·
(1 - e
-
t
/T
)
I = filter input (step)
O = filter output
t = time
T = filter time constant
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...