Program features
127
Settings
Diagnostics
Application message blocking
You can use parameter
APL LIM WRN MASK to block the application
messages if you do not need the messages. When a message is blocked, the
relevant function remains in use, but the message itself is not shown on the control
panel display and in the PC tool history.
You can activate or deactivate the messages by setting or resetting the individual
message masking bits. Bit value “1” activates the message: the combined value of
the bits has to be entered in integer format.
The messages and the corresponding masking bits are as follows:
Parameter
Additional information
Selection of Load speed control
Setting of time period for holding the speed reference at base speed
Setting of speed limits according to motor current at the base speed
Actual signal
Additional information
bit 10
Load speed control error bit
bit 5
bit 6
Speed is limited in the forward direction by the Load speed control function
Speed is limited in the reverse direction by the Load speed control function
Warnings
Speed limited in the forward direction by the Load speed control function
Speed limited in the reverse direction by the Load speed control function
Bit
Messages
Default
0
SLOW DOWN UP (FFF4)
SLOW DOWN DOWN (FFF5)
0
1
HIGHEND LIMIT (FFF6)
LOWEND LIMIT (FFF7)
0
2
LOAD SP UP LIM (FFB8)
LOAD SP DW LIM (FFB9)
0
3
JOYSTICK CHECK (FFFA)
1
4
ZERO POS WARN (FFFB)
1
5
START HIGH (FFB3)
1
6
HOMING ACTIVE (FFB1)
HOMING DONE (FFB0)
1
7
FLWR1 LIM/FLT (FFFD)
FLWR2 LIM/FLT (FFFE)
FLWR3 LIM/FLT (FFB5)
FLWR4 LIM/FLT (FFB4)
1
8
MASTERLIM/FLT (FFB2)
1
9
START INTERLOCK
1
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...