Control panel
47
Function mode
In the Function Mode, you can:
• upload the drive parameter values and motor data from the drive to the panel.
• download group 1 to 97 parameter values from the panel to the drive.
1)
• adjust the contrast of the display.
The panel enters the Function Mode when you press the
FUNC
key.
How to upload data from a drive to the panel
Note:
• Upload before downloading.
• Ensure the firmware of the destination drive is the same (for example, standard
firmware).
• Before removing the panel from a drive, ensure the panel is in remote operating
mode (change with the LOC/REM key).
• Stop the drive before downloading.
Before upload, repeat the following steps in each drive:
• Setup the motors.
• Activate the communication to the optional equipment. (See parameter group
Before upload, do the following in the drive from which the copies are to be taken:
• Set the parameters in groups 10 to 97 as preferred.
• Proceed to the upload sequence (below).
Step
Action
Press Key
Display
1.
Enter the Function Mode.
1 L
->
1242.0 rpm O
UPLOAD <=<=
DOWNLOAD =>=>
CONTRAST 4
2.
Select the upload function (a flashing cursor indicates the
selected function).
1 L
->
1242.0 rpm O
UPLOAD <=<=
DOWNLOAD =>=>
CONTRAST 4
3.
Enter the upload function.
1 L
->
1242.0 rpm O
UPLOAD <=<=
4.
Switch to external control.
(No L on the first row of the display.)
1
->
1242.0 rpm O
UPLOAD <=<=
DOWNLOAD =>=>
CONTRAST 4
1)
By default, the parameter groups 98, 99 and the results of the motor identification are not included. The restriction
prevents downloading of unfit motor data. In special cases it is, however, possible to download all. For more information,
please contact your local ABB representative.
FUNC
ENTER
LOC
REM
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...