Actual signals and parameters
162
AI1/JOYST
Unipolar analogue input AI1 as joystick. The minimum input signal runs the
motor at the maximum reference in the reverse direction, the maximum input at
the maximum reference in the forward direction.
Note:
Parameter
REF DIRECTION must have the value REQUEST.
Start DI direction, if used (
) overwrites the joystick direction.
WARNING!
Minimum reference for joystick must be higher than 0.5 V.
Set parameter
MINIMUM AI1 to 2 V or to a value higher than
0.5 V and analogue signal loss detection parameter
AI<MIN
FUNCTION to FAULT. The drive will stop in case the control signal is lost.
Note:
If the signal is bipolar (±10 V DC), use the selection AI1 BIPOLAR. The
selection AI1/JOYST ignores the negative signal range.
5
AI2/JOYST
See selection AI1/JOYST.
6
DI3U,4D(R)
Digital input 3: Reference increase. Digital input DI4: Reference decrease.
Stop command or power switch off resets the reference to zero. Parameter
ACCEL TIME 2 defines the rate of the reference change.
7
DI3U,4D
Digital input 3: Reference increase. Digital input DI4: Reference decrease. The
program stores the active speed reference (not reset with a Stop command or
power switch-off). Parameter
ACCEL TIME 2 defines the rate of the
reference change.
8
DI5U,6D
See selection DI3U, 4D.
9
COMM. REF
Fieldbus reference REF1
10
FAST COMM
As with the selection COMM. REF, except the following differences:
- shorter communication cycle time when transferring the reference to the core
motor control program (6 ms -> 2 ms)
- the direction cannot be controlled through interfaces defined with parameters
Note:
If any of the following selections is true, the selection is not effective.
Instead, the operation is according to COMM. REF.
- parameter
MOTOR CTRL MODE is SCALAR
11
AI5
Analogue input AI5
12
AI5/JOYST
See selection AI1/JOYST.
13
AI6/JOYST
See selection AI1/JOYST.
14
DI11U,12D(R)
See selection DI3U,4D(R).
15
Index
Name/Selection
Description
FbEq
0
10
6
2
AI1
Speed Reference (REF1)
11.04
-
11.04
-
11.05
11.05
Par. 13.01 = 2 V, Par. 13.02 = 10 V
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...