Additional data: actual signals and parameters
320
Actual signals
Index Name
Short name
FbEq
Unit
Range
PB
01
ACTUAL SIGNALS
01.02 SPEED
SPEED
-20000 = -100%
20000 = 100% of
motor absolute max.
speed
rpm
2
01.03 FREQUENCY
FREQ
-100 = -1 Hz 100 = 1
Hz
Hz
3
01.04 CURRENT
CURRENT
10 = 1 A
A
4
01.05 TORQUE
TORQUE
-10000 = -100%
10000 = 100% of
motor nominal torque
%
5
01.06 POWER
POWER
-1000 = -100% 1000
= 100% of motor
nominal power
%
6
01.07 DC BUS VOLTAGE V
DC BUS V
1 = 1 V
V
7
01.08 MAINS VOLTAGE
MAINS V
1 = 1 V
V
8
01.09 OUTPUT VOLTAGE
OUT VOLT
1 = 1 V
V
9
01.10 ACS800 TEMP
ACS TEMP
1 = 1°C
°C
10
01.11 EXTERNAL REF 1
EXT REF1
1 = 1 rpm
rpm
11
01.12 EXTERNAL REF 2
EXT REF2
0 = 0% 10000 =
100% 1)
%
12
01.13 CTRL LOCATION
CTRL LOC
(1,2) LOCAL; (3)
EXT1; (4) EXT2
LOCAL; EXT1;
EXT2
13
01.14 OP HOUR COUNTER OP HOUR
1 = 1 h
h
14
01.15 KILOWATT HOURS
KW HOURS
1 = 100 kWh
kWh
15
01.17 DIL DI6-1 STATUS
DIL DI6-1
1 = 1
17
01.18 AI1 [V]
AI1 [V]
1 = 0.001 V
V
18
01.19 AI2 [mA]
AI2 [mA]
1 = 0.001 mA
mA
19
01.20 AI3 [mA]
AI3 [mA]
1 = 0.001 mA
mA
20
01.21 RO3-1 STATUS
RO3-1
1 = 1
21
01.22 AO1 [mA]
AO1 [mA]
1 =0.001 mA
mA
22
01.23 AO2 [mA]
AO2 [mA]
1 = 0.001 mA
mA
23
01.27 APPLICATION MACRO MACRO
1 … 5
According to
parameter 99.02
27
01.28 EXT AO1 [mA]
EXT AO1
1 = 0.001 mA
mA
28
01.29 EXT AO2 [mA]
EXT AO2
1 = 0.001 mA
mA
29
01.30 PP 1 TEMP
PP 1 TEM
1 = 1°C
°C
30
01.31 PP 2 TEMP
PP 2 TEM
1 = 1°C
°C
31
01.32 PP 3 TEMP
PP 3 TEM
1 = 1°C
°C
32
01.33 PP 4 TEMP
PP 4 TEM
1 = 1°C
°C
33
01.35 MOTOR 1 TEMP
M1 TEMP
1 = 1°C
°C
35
01.36 MOTOR 2 TEMP
M2 TEMP
1 = 1°C
°C
36
01.37 MOTOR TEMP EST
MOTOR TE
1 = 1°C
°C
37
01.38 AI5 [mA]
AI5 [mA]
1 = 0.001 mA
mA
38
01.39 AI6 [mA]
AI6 [mA]
1 = 0.001 mA
mA
39
01.40 DI15-7 STATUS
DI15-7
1 = 1
40
01.41 EXT RO STATUS
EXT RO
1 = 1
41
01.42 PROCESS SPEED REL P SPEED
1 = 1
%
42
01.43 CRANE OPT TIME
CR OPTTIME
1 = 10 h
h
43
01.44 FAN ON-TIME
FAN TIME
10 h = 1
h
44
01.45 CTRL BOARD TEMP
CTRL B T
1 = 1
°C
45
01.46 OEM SIGNAL
OEM PAR
46
02
ACTUAL SIGNALS
02.01 SPEED REF 2
S REF 2
0 = 0% 20000 =
100% of motor
absolute max. speed
rpm
51
02.02 SPEED REF 3
S REF 3
rpm
52
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...