Actual signals and parameters
194
34.05
TORQ ACT FILT TIM
Defines a filter time for the actual signal torque (actual signal
). Affects
also on the torque read through an analogue output.
0 … 20000 ms
Filter time constant
0 … 20000
35 MOT TEMP MEAS
Motor temperature measurement. For the function description, see sections
Motor temperature measurement through the standard I/O interface
on page
Motor temperature measurement through an analogue I/O extension
on page
.
35.01
MOT 1 TEMP AI1 SEL Activates the motor 1 temperature measurement function and selects the
sensor type.
Note:
If an optional analogue I/O extension module RAIO is used for the
temperature measurement and
MOT 1 TEMP AI1 SEL and/or
MOT 2 TEMP AI2 SEL are set to 1xPT100, analogue extension module input
signal range must be set to 0 ... 2 V (instead of 0 ... 10 V) with DIP switches.
NOT IN USE
The function is inactive.
1
1xPT100
The function is active. The temperature is measured with one Pt 100 sensor.
Analogue output AO1 feeds constant current through the sensor. The sensor
resistance increases as the motor temperature rises, as does the voltage over
the sensor. The temperature measurement function reads the voltage through
analogue input AI1 and converts it to degrees centigrade.
2
2XPT100
The function is active. Temperature is measured using two Pt 100 sensors.
See selection
3
3XPT100
The function is active. Temperature is measured using three Pt 100 sensors.
See selection
4
Index
Name/Selection
Description
FbEq
63
%
100
T
t
Filtered signal
Unfiltered signal
O = I
·
(1 - e
-
t
/T
)
I = filter input (step)
O = filter output
t = time
T = filter time constant
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...