Adaptive Programming examples for crane control
297
Adaptive Programming examples for crane control
Chapter overview
This chapter includes examples of Adaptive Programming (AP) for Crane control
program (+N697).
For more information on Adaptive Programming, see
on page
Application Guide for Adaptive Program
(3AFE64527274 [English]). For information on DriveAP (a Windows-based tool for
Adaptive Programming), see
DriveAP User’s Manual
(3AFE64540998 [English]).
Note:
If you use and/or change the AP blocks used in the Crane control program
made by ABB, you are responsible for the software and the application.
Main contactor control logic
Using the Adaptive Programming (AP), you can create a main contactor control logic
for the 3-phase power supply of the ACS800 drive. With the help of the main
contactor control logic, the power supply of the drive is disabled when the crane is
not used (the standby energy-efficiency mode).
For this, you must have the +24 V DC external auxiliary voltage supplied to the
RMIO board (see
External 24 V supply of RMIO board
). You can use a
RMIO or RDIO relay output for controlling the main contactor, and you can close the
main contactor with a command through a dedicated digital input of RMIO or RDIO.
For more information, see the
Application Guide for Adaptive Program
(3AFE64527274 [English]) and
DriveAP User’s Manual
(3AFE64540998 [English]).
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...