Additional data: actual signals and parameters
325
13.12
MAXIMUM AI3
20 mA
187
13.13
SCALE AI3
100%
188
13.14
FILTER AI3
0.10 s
189
13.15
INVERT AI3
NO
190
13.16
MINIMUM AI5
0 mA
191
13.17
MAXIMUM AI5
20 mA
192
13.18
SCALE AI5
100%
193
13.19
FILTER AI5
0.10 s
194
13.20
INVERT AI5
NO
195
13.21
MINIMUM AI6
0 mA
196
13.22
MAXIMUM AI6
20 mA
197
13.23
SCALE AI6
100%
198
13.24
FILTER AI6
0.10 s
199
13.25
INVERT AI6
NO
200
14
RELAY OUTPUTS
14.01
RO PTR1
+003.013.06
201
14.02
RO PTR2
+003.002.02
202
14.03
RO PTR3
-.003.002.03
203
14.10
RO PTR4
0
210
14.11
RO PTR5
0
211
14.12
RO PTR6
0
212
14.13
RO PTR7
0
213
14.14
RO PTR8
0
214
14.15
RO PTR9
0
215
15
ANALOGUE OUTPUTS
15.01
AO1 PTR
+.001.002.00
226
15.02
INVERT AO1
NO
227
15.03
MINIMUM AO1
0 mA
228
15.04
FILTER AO1
0.10 s
229
15.05
SCALE AO1
100%
230
15.06
AO2 PTR
+.001.005.00
231
15.07
INVERT AO2
NO
232
15.08
MINIMUM AO2
0 mA
233
15.09
FILTER AO2
2.00 s
234
15.10
SCALE AO2
100%
235
16
SYST CTRL INPUTS
16.01
RUN ENABLE
YES
251
16.02
PARAMETER LOCK
OPEN
252
16.03
PASS CODE
0
253
16.04
FAULT RESET SEL
NOT SEL
254
16.05
USER MACRO IO CHG
NOT SEL
255
16.06
LOCAL LOCK
OFF
256
16.07
PARAMETER SAVE
DONE
257
16.08
RUN ENA PTR
0
258
16.09
CTRL BOARD SUPPLY
INTERNAL 24V
259
16.11
FAULT RESET PTR
0
261
16.12
POWER ON RESET TD
10 s
262
16.13
USER MACRO PTR
0
263
16.14
FAN KWH CNT RESET
NOT SEL
20
LIMITS
20.01
MINIMUM SPEED
(calculated)
351
20.02
MAXIMUM SPEED
(calculated)
352
20.03
MAXIMUM CURRENT
type-specific
353
20.04
TORQ MAX LIM1
300%
354
20.05
OVERVOLTAGE CTRL
OFF
355
20.06
UNDERVOLTAGE CTRL
ON
356
20.07
MINIMUM FREQ
- 50 Hz
357
20.08
MAXIMUM FREQ
50 Hz
358
Index
Name/Selection
User
Default
PB
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...