Quick start-up guide
32
• Select the drive mode as speed/torque (Par.
• Select the number of Followers attached to the drive (Par.
• Select the mode of the Follower drives (Par.
• Select the signal to be sent to the Follower as reference 1 (Par.
). For
example: 202 for speed.
• Select the signal to be sent to the Follower as reference 2 (Par.
). For
example: 213 for torque.
• Select the CH2 link topology as ring (Par.
Set the following parameters in the Follower drive.
• Select the control location as EXT2 (Par.
• Select the drive as a Follower (Par.
• Select the drive mode as speed/torque (Par.
). The torque mode should be
selected if the Follower is to run in the load sharing mode.
• Select the control location as EXT2(Par.
).
• Select the Start/Stop control as COMM.CW if the Master command is to be used
(Par.
for EXT2).
• Select the direction control as REQUEST (Par.
).
• Select the drive reference control as COMM.REF/FAST COMM. (Par.
EXT2). The FAST COMM selection should be used if the load sharing parameter
(Par.
) is to be functional.
• Set the load sharing factor (Par.
).
• Set the minimum reference limits (Par.
for EXT2).
• Set the maximum reference limits (Par.
• Select the CH2 communication link topology as ring (Par.
).
For hoist applications, both the Master and the Follower should have the pulse
encoder in use for speed feedback. Set the following parameters for encoder
configuration:
• Select the encoder module type (Par.
).
• Set the encoder PPR (Par.
• Select the speed measurement mode (Par.
• Select the speed feedback selection as ENCODER (Par.
).
• Configure the encoder fault (Par.
See section
Master/Follower use of several drives (Only in EXT2 Control)
for more
information.
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...