Actual signals and parameters
161
11 REFERENCE
SELECT
Panel reference type, external control location selection and external reference
sources and limits
11.01
KEYPAD REF SEL
Selects the type of the reference given from panel.
REF1 (rpm)
Speed reference in rpm. (Frequency reference (Hz) if parameter
SCALAR.)
1
REF2 (%)
%-reference. The use of REF2 vary depending on the application. For
example, if the Torque Control using M/F is selected, REF2 is the torque
reference.
2
11.02
EXT1/EXT2 SELECT
Defines the source from which the drive reads the signal that selects between
the two external control locations, EXT1 or EXT2.
Note
: In M/F configuration, EXT2 should be used for control in M/F mode and
EXT1 for stand-alone mode.
EXT1
EXT1 active. The control signal sources are defined with parameter
and
1
EXT2
EXT2 active. The control signal sources are defined with parameter
and
2
COMM.CW
bit 11 on page
3
DI7
Digital input DI7 is the signal source.
4
DI8
Digital input DI8 is the signal source.
5
DI9
Digital input DI9 is the signal source.
6
DI10
Digital input DI10 is the signal source.
7
PARAM 11.09
Source selected with parameter
8
11.03
EXT REF1 SELECT
Selects the signal source for external reference REF1
Note
: In M/F configuration, EXT2 should be used for M/F mode and EXT1 for
stand-alone mode.
KEYPAD
Control panel. The first line on the display shows the reference value.
1
AI1
Analogue input AI1.
Note:
If the signal is bipolar (±10 V DC), use the selection AI1 BIPOLAR. (The
selection AI1 ignores the negative signal range.)
2
AI2
Analogue input AI2.
3
AI3
Analogue input AI3.
4
Index
Name/Selection
Description
FbEq
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...