Actual signals and parameters
201
50.07
ENC CABLE CHECK
Selects the drive operation when encoder signal is missing.
Note:
Monitoring is only for RTAC-03. For more information, see
RTAC-03
TTT Pulse Encoder Interface Module User’s Manual
[3AFE68650500
(English)]
DISABLED
Not active
1
WARNING
Drive generates warning ENC CABLE.
2
FAULT
The drive trips on ENC CABLE.
3
51 COMM MODULE
DATA
The parameters are visible and need to be adjusted, only when a fieldbus
adapter module (optional) is installed and activated with parameter
. For
details on the parameters, refer to the manual of the fieldbus module and
chapter
These parameter settings will remain the same even though the macro is
changed.
52 STANDARD
MODBUS
The settings for the Standard Modbus Link. See chapter
.
52.01
STATION NUMBER
Defines the address of the device. Two units with the same address are not
allowed on-line.
1 … 247
Address
1 = 1
52.02
BAUDRATE
Defines the transfer rate of the link.
600
600 bit/s
1
1200
1200 bit/s
2
2400
2400 bit/s
3
4800
4800 bit/s
4
9600
9600 bit/s
5
19200
19200 bit/s
6
52.03
PARITY
Defines the use of parity and stop bit(s). The same setting must be used in all
on-line stations.
NONE1STOPBIT
No parity bit, one stop bit
1
NONE2STOPBIT
No parity bit, two stop bits
2
ODD
Odd parity indication bit, one stop bit
3
EVEN
Even parity indication bit, one stop bit
4
60 MASTER/
FOLLOWER
Master/Follower application. For more information, see section
Follower use of several drives (Only in EXT2 Control)
on page
and a
separate
Master/Follower Application Guide
[3AFE64590430 (English)].
60.01
MASTER LINK MODE Defines the role of the drive on the Master/Follower link.
Note:
Master/Follower configuration will work with complete functionality only
when the drive is in
EXT2
control. EXT1 control can be used for the drive to be
a stand-alone drive with M/F link active.
Two Master stations are not allowed on-line. If a Follower drive is changed to
be a Master drive (or vice versa) with this parameter, the RMIO board must be
powered up again for the M/F link to work properly.
NOT IN USE
The Master/Follower link is not active.
1
MASTER
Master drive
2
FOLLOWER 1
Follower drive
3
FOLLOWER 2
Follower drive
4
FOLLOWER 3
Follower drive
5
Index
Name/Selection
Description
FbEq
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...