Fieldbus control
239
0 … 8999
Defines the drive parameter into which the value of fieldbus reference
REF8 is written.
Format:
see parameter 90.01.
1 (Standard) or
10 (Multidrive)
This parameter selects the source from which the drive reads the Main
Reference data set (comprising the fieldbus Control Word, fieldbus
reference REF1, REF2, REF3, REF4 and REF5).
ACTUAL SIGNAL SELECTION FOR FIELDBUS
302 (Fixed)
The Status Word is transmitted to as the first word of the Main Actual Signal
data set.
0 … 9999
Selects the Actual signal or parameter value to be transmitted as the
second word (ACT1) of the Main Actual Signal data set.
Format:
(
x
)
xyy,
where (
x
)
x
= actual signal group or parameter group,
yy
=
actual signal or parameter index. For example,
103
= actual signal 1.03
FREQUENCY;
2202
= parameter 22.02 ACCEL TIME 1.
Note:
With the Generic Drive communication profile active (Par. 98.07 =
GENERIC), this parameter is fixed to
102
(actual signal 1.02 SPEED – in
DTC motor control mode) or
103
(1.03 FREQUENCY – in Scalar mode).
0 … 9999
Selects the actual signal or parameter value to be transmitted as the third
word (ACT2) of the Main Actual Signal data set.
Format:
see parameter 92.02.
0 … 9999
Selects the actual signal or parameter value to be transmitted as the first
word (ACT3) of the Auxiliary1 Actual Signal data set.
Format:
see parameter 92.02.
0 … 9999
Selects the actual signal or parameter value to be transmitted as the
second word (ACT4) of the Auxiliary1 Actual Signal data set.
Format:
see parameter 92.02.
0 … 9999
Selects the actual signal or parameter value to be transmitted as the third
word (ACT5) of the Auxiliary1 Actual Signal data set.
Format:
see parameter 92.02.
0 … 9999
Selects the actual signal or parameter value to be transmitted as the first
word (ACT6) of the Auxiliary2 Actual Signal data set.
Format:
see parameter 92.02.
0 … 9999
Selects the actual signal or parameter value to be transmitted as the
second word (ACT7) of the Auxiliary2 Actual Signal data set.
Format:
see parameter 92.02.
0 … 9999
Selects the actual signal or parameter value to be transmitted as the third
word (ACT8) of the Auxiliary2 Actual Signal data set.
Format:
see parameter 92.02.
-255.255.31…+255.255.31
/ C.-32768 … C.32767
Selects the address from which the 03.02 Main Status Word bit 10 is read
from.
-255.255.31…+255.255.31
/ C.-32768 … C.32767
Selects the address from which the 03.02 Main Status Word bit 13 is read
from.
Parameter
Setting for
fieldbus control
Function/Information
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...