Actual signals and parameters
163
DI11U,12D
See selection DI3U,4D.
16
PARAM 11.10
EXT1 REF PTR.
17
AI1 BIPOLAR
Bipolar analogue input AI1 (-10 … 10 V). The figure below illustrates the use of
the input as the speed reference.
Note:
Start DI direction, if used (
) overwrites the joystick
direction.
18
Index
Name/Selection
Description
FbEq
Spee
d R
eference
minAI1
=
MINIMUM AI1
maxAI1
=
MAXIMUM AI1
scaled maxREF1
=
SCALE AI1 x 11.05 EXT REF1 MAXIMUM
minREF1
=
11.04 EXT REF1 MINIMUM
scaled
minREF1
-minAI1
minAI1
maxAI1
-maxAI1
-minREF1
-scaled
Analogue Input signal
Operation Range
maxREF1
maxREF1
10.03 REF
DIRECTION =
FORWARD or
REQUEST
10.03 REF
DIRECTION =
REVERSE or
REQUEST
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...