Application macros, control location EXT1/EXT2
131
Default control connections
The figure below shows the external control connections for the Crane macro. The
markings of the standard I/O terminals on the RMIO board are shown.
X20
1
VREF
Reference voltage -10 V DC
2
GND
1 kohm <
R
L
< 10 kohm
X21
1
VREF
Reference voltage 10 V DC
1 kohm <
R
L
< 10 kohm
2
GND
3
AI1+
Speed reference 0(2) … 10 V,
R
in
> 200 kohm
4
AI1-
5
AI2+
By default, not in use. 0(4) … 20 mA
, R
in
=
100 ohm
6
AI2-
7
AI3+
By default, not in use. 0(4) … 20 mA
, R
in
=
100 ohm
8
AI3-
9
AO1+
Motor speed 0(4) … 20 mA 0 … motor nom.
speed,
R
L
< 700 ohm
10
AO1-
11
AO2+
Output current 0(4) … 20 mA 0 … motor
nom. current,
R
L
< 700 ohm
12
AO2-
X22
1
DI1
Forward Start
2)
2
DI2
Reverse Start
1, 2)
3
DI3
4
DI4
5
DI5
6
DI6
7
+24 V
+24 V DC, max. 100 mA
8
+24 V
9
DGND1 Digital ground
10
DGND2 Digital ground
11
DI IL
Start interlock (0 = stop)
3)
X23
1
+24 V
Auxiliary voltage input/output, non-isolated,
24 V DC, 250 mA
4)
2
GND
X25
1
RO11
Relay output 1
Open Brake
2
RO12
3
RO13
X26
1
RO21
Relay output 2
Running
2
RO22
3
RO23
X27
1
R031
Relay output 3
Inverted fault
2
R032
3
R033
=
=
A
rpm
1)
should be
REQUEST.
2)
The US default settings differ as
follows:
3)
See the wiring diagram on page
if used as power ackn signal.
4)
+24 V DC external auxiliary
voltage to the RMIO board.
For more information, see
on page
DI1 DI2 Operation
0
0
Stop
1
0
Start Forward
0
1
Start Reverse
1
1
Stop
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...