Actual signals and parameters
208
77.10
CURRENT X4 FWD
Defines the current in amps expected at the base speed in forward direction for
limiting the speed reference to the value in parameter
This current can be the current at the base speed with maximum load when
running in the forward direction.
0.0 … 3000.0 A
Setting range in amps.
0 … 30000
77.11
REF Y4 FWD
Defines the speed in rpm to be used as the speed limit in forward direction, if
the current at the base speed in forward direction is equal to the value in
parameter
CURR X4 FWD. This value can be the minimum allowed
speed in maximum load condition in the forward direction.
0.0 … 18000.0 rpm
Setting range in rpm.
0 … 180000
77.12
CURRENT X1 REV
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
current can be the empty hook current at the base speed when running in the
reverse direction.
0.0 … 3000.0 A
Setting range in amps.
0 … 30000
77.13
REF Y1 REV
Defines the speed in rpm to be used as the speed limit in forward direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
CURR X1 REV. This value can be the maximum allowed
speed in empty hook condition in the reverse direction.
0.0 … 18000.0 rpm
Setting range in rpm.
0 … 180000
77.14
CURRENT X2 REV
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
REF Y2 REV.
0.0 … 3000.0 A
Setting range in amps.
0 … 30000
77.15
REF Y2 REV
Defines the speed in rpm to be used as the speed limit in reverse direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
0.0 … 18000.0 rpm
Setting range in rpm.
0 … 180000
77.16
CURRENT X3 REV
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
REF Y3 REV.
0.0 … 3000.0 A
Setting range in amps.
0 … 30000
77.17
REF Y3 REV
Defines the speed in rpm to be used as the speed limit in reverse direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
0.0 … 18000.0 rpm
Setting range in rpm.
0 … 180000
77.18
CURRENT X4 REV
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
current can be the current at the base speed with maximum load when running
in the reverse direction.
0.0 … 3000.0 A
Setting range in amps.
0 … 30000
77.19
REF Y4 REV
Defines the speed in rpm to be used as the speed limit in reverse direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
CURR X4 REV. This value can be the minimum allowed
speed in maximum load condition in the reverse direction.
0.0 … 18000.0 rpm
Setting range in rpm.
0 … 180000
Index
Name/Selection
Description
FbEq
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...