Fieldbus control
259
Fieldbus reference scaling
With the Generic Drive communication profile active, the speed reference value
received from the fieldbus and the actual speed value received from the drive are
scaled as shown in the table below.
Note:
Any correction of the reference (see section
applied before scaling.
Ref.
No.
Application
Macro used
(par. 99.02)
Range
Reference
type
Speed reference
scaling
Actual speed
scaling*
Notes
REF1
(any)
-32768...
32767
Speed or
Frequency
0 = 0
20000 =
[par. 99.08 (DTC) /
99.07 (scalar)]**
0 = 0
20000 =
[par.
99.08 (DTC) /
99.07 (scalar)]**
REF2
Crane macro
with speed
mode
-32768...
32767
Speed or Freq.
(not with
FAST COMM)
-20000 =
-[par. 11.08]
-1 =
-[par. 11.07]
0 =
[par. 11.07]
20000 =
[par. 11.08]
0 = 0
20000 =
[par.
99.08 (DTC) /
99.07 (scalar)]**
Final reference
limited with
20.01/20.02
[speed] or
20.07/20.08
[frequency]
Speed or Freq.
with
FAST COMM
-20000 =
-[par. 11.08]
0 = 0
20000 =
[par. 11.08]
0 = 0
20000 =
[par.
99.08 (DTC) /
99.07 (scalar)]**
Final reference
limited with
20.01/20.02
[speed] or
20.07/20.08
[frequency]
Crane macro
with M/F in
torque mode
-32768...
32767
Torque
(not with
FAST COMM)
-10000 =
-[par. 11.08]
-1 =
-[par. 11.07]
0 =
[par. 11.07]
10000 =
[par. 11.08]
0 = 0
20000 =
[par.
99.08 (DTC) /
99.07 (scalar)]**
Final reference
limited with 20.04
Torque with
FAST COMM
-10000 =
-[par. 11.08]
0 = 0
10000 =
[par. 11.08]
0 = 0
20000 =
[par.
99.08 (DTC) /
99.07 (scalar)]**
Final reference
limited with 20.04
* With DTC the filter time of the actual speed value can be adjusted using parameter 34.04.
**
Note:
The maximum reference value is 163% (that is,163% = 1.63 · value of parameter 99.08/99.07 value).
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...