R&S FSP
Remote Control – Description of Commands
Differences in GPIB Behavior between the FSP and the FSE Families of Instruments
6.286
Operating Manual 1164.4556.12 - 06
R&S
FSP
FSE
CALCulate<1|2>:LIMit<1...8>:LOWer[:DATA] <numeric
value>
FSE
CALCulate<1|2>:LIMit<1...8>:MARGin
0 to 100DB
not available for
R&S FSP, FSET and
ESIB
R&S
FSP
FSE
CALCulate<1|2>:LIMit<1...8>:NAME
1 to 8|<string>
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
MODulation:EXCeptions?
ARFCn | TXBand |
RXBand| COMBined |
DCSRx1800
not available for
R&S FSP, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
MODulation:FAILs?
ARFCn | TXBand |
RXBand| COMBined |
DCSRx1800
not available for
R&S FSP, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
MODulation?
ARFCn | TXBand |
RXBand| COMBined |
DCSRx1800
not available for
R&S FSP, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
SWITching:FAILs?
not available for
R&S FSP, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
SWITching?
not available for
R&S FSP, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPURious:FAILs?
TXBand | OTXBand|
RXBand | IDLeband
not available for
R&S FSP, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPURious?
TXBand | OTXBand|
RXBand | IDLeband
not available for
R&S FSP, FSET and
ESIB
R&S
FSP
FSE
CALCulate<1|2>:LIMit<1...8>:STATe
ON | OFF
R&S
FSP
FSE
CALCulate<1|2>:LIMit<1...8>:TRACe
1 to 3
R&S FSP: 3 traces are
available per screen
FSE: 4 traces are
available in full screen
mode and 2 traces per
screen in split screen
mode
R&S
FSP
CALCulate<1|2>:LIMit<1...8>:UNIT
DBM | DBPW | WATT |
DBUV | DBMV | VOLT |
DBUA | AMPere | DB |
DBUV_M | DBUA_M |
DEG | RAD | S | HZ |
PCT | UNITLESS
Available units are
compatible to the FSE
FSE/
FSIQ
CALCulate<1|2>:LIMit<1...8>:UNIT
DBM | DBPW | WATT |
DBUV | DBMV | VOLT |
DBUA | AMPere | DB |
DBUV_MHZ |
DBMV_MHZ |
DBUA_MHZ | |DBUV_M
| DBUA_M | DBUV_MHZ
| DBUA_MHZ | DEG |
RAD | S | HZ | PCT |
UNITLESS
only the following units
are available for the
R&S FSP:DBM | DBPW
| WATT | DBUV | DBMV |
VOLT | DBUA | AMPere |
DB | DBUV_M |
DBUA_M | DEG | RAD |
S | HZ | PCT |
UNITLESS
Devices
Command
(Sheet 7 of 47)
Parameter
Notes
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...