Operating Manual 1164.4556.12 - 06
4.159
R&S FSP
Instrument Functions
Basic Settings
FULL SCREEN
The
FULL SCREEN
softkey selects the display of one diagram. This corresponds to
the default setting of R&S FSP.
In the
FULL SCREEN
mode, it is possible to switch between two different device
settings by selecting the active window (screen A or screen B).
Switching between
SCREEN A
and
SCREEN B
is performed by means of the corre-
sponding key in the hotkey bar (for details refer to
“Mode Selection – Hotkey Bar” on
It should be noted that the measurements in the FULL SCREEN mode are per-
formed only in the visible (active) window.
The active window is marked by
or
on the right of the diagram.
Remote command:
DISP:FORM SING
DISP:WIND<1|2>:SEL
SPLIT
SCREEN
The
SPLIT SCREEN
softkey selects the display of two diagrams. The upper dia-
gram is designated
SCREEN A
, the lower diagram
SCREEN B
.
Switching between
SCREEN A
and
SCREEN B
is performed via the corresponding
key in the hotkey bar. The active window is marked by highlighting fields
and
on the right of the diagram.
Remote command:
DISP:FORM SPL
REF LEVEL
COUPLED
The
REF LEVEL COUPLED
softkey switches the coupling of the reference level on
and off. In addition to the reference level, the mixer level and input attenuation are
coupled with one another.
For the level measurement, the same reference level and input attenuation must be
set for the two diagrams.
Remote command:
INST:COUP RLEV
CENTER B =
MARKER A |
CENTER A =
MARKER B
The
CENTER B = MARKER A
and
CENTER A = MARKER B
softkeys couple the
center frequency in diagram B with the frequency of marker 1 in diagram A and the
center frequency in diagram B with the frequency of marker 1 in diagram B. The two
softkeys are mutually exclusive.
This coupling is useful, e.g. for viewing the signal at the marker position in diagram
A with higher frequency resolution or in the time domain in diagram B.
If marker 1 is off, it is switched on and set to the maximum of the trace in the active
diagram.
Remote command:
INST:COUP CF_B
INST:COUP CF_A
A
B
A
B
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...