Parameter:
For allowed <rbw> setting for <filter type> = CFILter and <filter type> = RRC see section
Bandwidths and Sweep Time – BW Key”
“List of Available Channel Filters” on page 4.25
Return value:
The query command returns a list of comma-separated values (CSV) which contains the power
measurement results in floating-point format. The unit depends on the setting with
CALC:UNIT.
<analyzer freq>:
Receive frequency for the signal to be measured (= center frequency in manual
operation)
Range of values:
0 Hz to max. frequency, depending on the instrument
model.
<ref level>:
Reference level
Range of values:
+30 dBm to -70 dBm in 10 dB steps
+30 dBm to -75 dBm in 5 dB steps with El. Attenuator
option B25
<rf att>:
RF input attenuation
Range of values:
0 dB to 70 dB in 10 dB steps
0 dB to 75 dB in 5 dB steps with El. Attenuator Option
B25
<el att>:
RF input attenuation of electronic attenuator
Range of values:
0 dB to 30 dB in 10 dB steps
OFF
electronic attenuator not in signal path
If option B25 is missing, OFF is to be used.
<filter type>:
NORMal:
normal resolution filter
CFILter:
channel filter. These are especially steep-edged
filters, which are used for example in Fast ACP
measurement to ensure the band-limiting of a
transmission channel in the time domain.
RRC:
Root Raised Cosine filter. This special filter form is
used to determine the channel power for some mobile
radio standards.
<rbw>:
Resolution bandwidth
Range of values:
10 Hz to 10 MHz in 1, 3, 10 steps for <filter type> =
NORMal.
See filter table for <filter type> = CFILter and <filter
type> = RRC. For possible combinations of filter type
and filter bandwidth see table "List of available
channel filters" in chapter
,
“Setting the Bandwidths and Sweep Time –
.
<vbw>:
Video bandwidth
Range of values:
1 Hz to 10 MHz in 1, 3, 10 steps.
The value is ignored for <filter type> = CFILter or RRC
<meas time>:
Measurement time
Range of values:
1us to 30s
<trigger level>:
Reserved. Must be set to 0.
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...