Operating Manual 1164.4556.12 - 06
4.197
R&S FSP
Instrument Functions
Basic Settings
SELECT ITEMS
The
SELECT ITEMS
softkey sets the focus on the Items field to select the appropri-
ate item to be stored.
ENABLE ALL
ITEMS
The
ENABLE ALL ITEMS
softkey marks all partial data sets.
Remote command:
MMEM:SEL:ALL
DISABLE ALL
ITEMS
The
DISABLE ALL ITEMS
softkey deselects all partial data sets.
Remote command:
MMEM:SEL:NONE
DELETE FILE
The
DELETE FILE
softkey sets the focus on the File Name field to enter the file
name to be deleted. Alternatively the file to be deleted can be choosen from the
Files list. A message box opens to confirm the deletion.
Remote command:
MMEM:DEL "test03"
NEW FOLDER
The
NEW FOLDER
softkey opens an on-screen keyboard to enter a new folder
name.
DEFAULT
CONFIG
The
DEFAULT CONFIG
softkey establishes the default selection of the data subset
to be saved and outputs
DEFAULT
in the
ITEMS
field of the
SAVE/RECALL DATA
SET
table.
Remote command:
MMEM:SEL:DEF
STARTUP
RECALL
The
STARTUP RECALL
softkey activates the selection of a data set which is auto-
matically loaded when the instrument is powered on and after
PRESET
. For this pur-
pose the Dialog
Startup Recall
is opened (analogously to
DATA SET LIST).
The field
Files
lists all data sets stored in the selected directory. The currently
selected data set is checked.
In addition to the data sets stored by the user, the data set
FACTORY
, which speci-
fies the settings of the instrument before it was last switched off (Standby), is always
present (when unit is delivered).
To select a data set, the entry focus is set to the corresponding entry by means of
the rotary knob and the data set is activated by pressing the rotary knob or the
ENTER
key.
If a data set other than
FACTORY
is chosen, this data set will be loaded when the
unit is switched on or after pressing the
PRESET
key. Any settings can be assigned
to the
PRESET
key.
Remote command:
MMEM:LOAD:AUTO 1,"D:\user\config\test02"
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...