![Rohde & Schwarz R&S FSP Series Скачать руководство пользователя страница 179](http://html.mh-extra.com/html/rohde-and-schwarz/rands-fsp-series/rands-fsp-series_operating-manual_1477864179.webp)
Operating Manual 1164.4556.12 - 06
4.107
R&S FSP
Instrument Functions
Analyzer Mode
Fig. 4.13 Display of the complementary cumulative distribution function (CCDF)
Alternate to the histogram display of the APD the Complementary Cumulative Distri-
bution Function (CCDF) can be displayed. It shows the probability of an amplitude
exceeding a specific value.
For the APD function the x-axis is scaled in absolute values in dBm, whereas for the
CCDF function the x-axis is scaled relative to the MEAN POWER measured.
Definitions:
Crest factor = peak voltage to rms
CCDF = complementary cumulative distribution function
During an active statistic measurement, the functions FULL SCREEN,
SPLIT SCREEN and selection of the active diagram via the SCREEN A / SCREEN
B hotkeys are disabled.
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...