English
42
WILO SE 02/2017 V4.1WE
• Have a specialist inspect the connection and correct
it as necessary
4 Excessive voltage differences on the three phases
• Have a specialist inspect the connection and the
switching system and correct if necessary
5 Incorrect direction of rotation
• Swap the 2 phases from the mains supply
6 Impeller impeded by adhesive material, blockages and/
or solid matter, increased current consumption
• Switch off the unit, secure it against being switched
on again and free the impeller or clean the intake
port
7 The pumped liquid is too dense
• Contact the manufacturer
9.0.3 Fault: Unit runs but does not pump
1 No pumped liquid
• Open the container intake or sliders
2 Intake blocked
• Clean the intake, slider, intake port or intake strainer
3 Impeller blocked or obstructed
• Switch off the unit, secure it against being switched
on again and free the impeller
4 Defective hose or pipeline
• Replace defective parts
5 Intermittent operation (cycles)
• Check the control panel
9.0.4 Fault: The unit runs, but not at the stated operating
levels
1 Intake blocked
• Clean the intake, slider, intake port or intake strainer
2 Slider in the discharge pipe closed
• Open the slider and constantly monitor the power
consumption
3 Impeller blocked or obstructed
• Switch off the unit, secure it against being switched
on again and free the impeller
4 Incorrect direction of rotation
• Replace two phases on the mains supply
5 Air in the system
• Check the pipelines, pressure shroud and/or hydrau-
lics, and bleed if necessary
6 Unit is pumping against excessive pressure
• Check the slider in the discharge pipe and open it
completely if necessary, use a different impeller or
contact the factory
7 Signs of wear
• Replace worn parts
• Check for solids in the pumped liquid
8 Defective hose or pipeline
• Replace defective parts
9 Inadmissible levels of gas in the pumped liquid
• Contact the factory
10 Two-phase operation
• Have a specialist inspect the connection and correct
it as necessary
11 Excessive decrease in the water table during operation
• Check the supply and capacity of the system, and
inspect the level control settings and functionality
9.0.5 Fault: The unit does not run smoothly and is noisy
1 Unit is running in an inadmissible operation range
• Check the operational data of the unit and correct if
necessary and/or adjust the operating conditions
2 The intake port, strainer and/or impeller is blocked
• Clean the intake port, strainer and/or impeller
3 The impeller is impeded
• Switch off the unit, secure it against being switched
on again and free the impeller
4 Inadmissible levels of gas in the pumped liquid
• Contact the factory
5 Two-phase operation
• Have a specialist inspect the connection and correct
it as necessary
6 Incorrect direction of rotation
• Replace two phases on the mains supply
7 Signs of wear
• Replace worn parts
8 Defective motor bearing
• Contact the factory
9 The unit is installed under mechanical strain
• Check the installation, use rubber spacers if neces-
sary
9.0.6 Further steps for troubleshooting
If the points listed here do not rectify the fault, con-
tact our customer service. They can help you as fol-
lows:
• Telephone or written support from customer service
• On-site support from customer service
• Inspection or repair of the unit at the factory
Please note that you may be charged for some ser-
vices provided by our customer support. For more
details, please contact customer service.
10 Spare parts
Spare parts can be ordered from the manufacturer’s
customer service. To avoid queries and incorrect
orders, the serial and/or article number must always be
supplied.
Technical changes reserved!
Summary of Contents for Sub TWU 3 P&P Series
Page 2: ...Fig 1 Fig 2 1 2 3 4 5 0 30 1 00 m min 0 20 m 1 2 2 3 4 5 6 7 8 9 10 11 12 13 2 5 11...
Page 4: ......
Page 6: ......
Page 245: ...Wilo Sub TWU 3 TWU 3 P P 245 1 1 1 1 2 2 1 3 1 4 1 4 1 1 5 1 6 1 7...
Page 246: ...246 WILO SE 02 2017 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1...
Page 247: ...Wilo Sub TWU 3 TWU 3 P P 247 2 1 2 DIN ANSI 2 2...
Page 248: ...248 WILO SE 02 2017 V4 1WE 2 3 VDE 2 4 CE 2 5 VDE 0100 2 6 2 7 IP 68 2 8 PT100...
Page 249: ...Wilo Sub TWU 3 TWU 3 P P 249 2 9 2 10 2 11 70 A 110 A 3 3 1 3 2 85 A...
Page 250: ...250 WILO SE 02 2017 V4 1WE 3 3 1 15 C 5 C 25 C 3 4 6...
Page 253: ...Wilo Sub TWU 3 TWU 3 P P 253 5 5 1 5 2 5 3 5 4...
Page 254: ...254 WILO SE 02 2017 V4 1WE Wilo 5 4 1 15 C 1 5 4 2 2 1 2 3 4 1 8 2 9 3 10 4 11 5 12 6 13 7...
Page 258: ...258 WILO SE 02 2017 V4 1WE 0 30 1 30 3 55 70 30 50 10 0 30 2 60 1000 500 400 IP 6 6 1 VDE...
Page 260: ...260 WILO SE 02 2017 V4 1WE 1 2 1 2 0 3 6 5 IP 6 5 1 5 6 5 2 6 6...
Page 261: ...Wilo Sub TWU 3 TWU 3 P P 261 5 2 5 1 7 7 1 3 C 5 7 2 7 2 1 40 C...
Page 263: ...Wilo Sub TWU 3 TWU 3 P P 263 75 439 5a 5b AbfG 524 02 91 689 8 1 8 2 8 2 1 8 3 8 3 1 1000...
Page 265: ...Wilo Sub TWU 3 TWU 3 P P 265 2 5 6 7 8 9 10 2 11 9 0 5 1 2 3 4 5 2 6 2 7 8 9 9 0 6 10...
Page 301: ...Wilo Sub TWU 3 TWU 3 P P 301 1 1 1 1 2 2 1 3 1 4 1 4 1 1 4 2 1 5 1 6 1 7 1 7 1 a...
Page 302: ...302 WILO SE 02 2017 V4 1WE 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Page 303: ...Wilo Sub TWU 3 TWU 3 P P 303 DIN ANSI 2 2 2 3 VDE 2 4 CE...
Page 304: ...304 WILO SE 02 2017 V4 1WE 2 5 VDE 0100 2 6 E RCD 2 7 IP 68 2 8 100 2 9...
Page 305: ...Wilo Sub TWU 3 TWU 3 P P 305 2 10 2 11 kW 70 dB A 110 dB A 3 3 1 3 2 3 3 1 85 dB A...
Page 306: ...306 WILO SE 02 2017 V4 1WE 15 C 5 C 25 C 3 C 4 6 3 4 4 4 1 4 1 1 DIN VDE 0100 702 46...
Page 309: ...Wilo Sub TWU 3 TWU 3 P P 309 5 4 Wilo 5 4 1 15 C 1 5 4 2 2 1 8 2 9 3 10 4 11 5 12 6 13 7...
Page 310: ...310 WILO SE 02 2017 V4 1WE 1 2 3 4 5 6 7 8 2 3 9 7 9 10 11 12 1 2 3 4 5...
Page 315: ...Wilo Sub TWU 3 TWU 3 P P 315 5 1 2 1 2 0 3 bar 6 5 IP 6 5 1 5 1 2...
Page 316: ...316 WILO SE 02 2017 V4 1WE 6 5 2 6 6 5 2 5 1 7 7 1 3 C 5 7 2...
Page 318: ...318 WILO SE 02 2017 V4 1WE Wilo 75 439 5a 5b AbfG 524 02 91 689 8 1 8 2 8 2 1 8 3 8 3 1 1000 V...
Page 320: ...320 WILO SE 02 2017 V4 1WE 6 7 8 9 10 11 9 0 5 1 2 3 4 5 6 7 8 9 9 0 6 10...
Page 340: ...340 WILO SE 02 2017 V4 1WE 1 1 1 1 2 2 1 3 1 4 1 4 1 1 4 2 1 5 1 6 1 7...
Page 341: ...I Wilo Sub TWU 3 TWU 3 P P 341 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Page 342: ...342 WILO SE 02 2017 V4 1WE DIN ANSI 2 2 2 3...
Page 343: ...I Wilo Sub TWU 3 TWU 3 P P 343 VDE 2 4 CE CE 2 5 VDE 0100 2 6 RCD 2 7 IP 68 2 8 PT100 2 9...
Page 344: ...344 WILO SE 02 2017 V4 1WE 2 10 2 11 70 110 A 3 3 1 3 2 85 A...
Page 345: ...I Wilo Sub TWU 3 TWU 3 P P 345 3 3 1 15 C 5 C 25 C 3 C 4 6 3 4 4 4 1...
Page 348: ...348 WILO SE 02 2017 V4 1WE 5 2 5 3 5 4 Wilo 5 4 1 15 C 1...
Page 354: ...354 WILO SE 02 2017 V4 1WE 0 3 5 1 2 1 2 0 3 6 5 IP 6 5 1 5 1 2...
Page 355: ...I Wilo Sub TWU 3 TWU 3 P P 355 6 5 2 6 6 5 2 5 1 7 7 1 3 C 5 7 2...
Page 359: ...I Wilo Sub TWU 3 TWU 3 P P 359 5 6 7 8 9 10 2 11 9 0 5 1 2 3 4 5 2 6 2 7 8 9 9 0 6 10...
Page 360: ...3LRQHHULQJ IRU RX 2 6 1RUWNLUFKHQVWUD H RUWPXQG HUPDQ 7 ZLOR ZLOR FRP ZZZ ZLOR FRP...