ESI Operation
992
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Extended Scan Interface (ESI)
Table 37-8. Quadrature Decoding PSM Table
Previous
Quadrature
Pair
Current
Quadrature
Pair
Movement
State Table Entry
Q6
Q2
Q1
Q3
Q0
Byte Code
Error
-1
+1
Current Quadrature
Pair
00
00
No Rotation
0
0
0
0
0
000h
00
01
Turns right, +1
0
0
1
0
1
003h
00
10
Turns left, -1
0
1
0
1
0
00Ch
00
11
Error
1
0
0
1
1
049h
01
00
Turns left
0
0
0
0
0
000h
01
01
No rotation
0
0
0
0
1
001h
01
10
Error
1
0
0
1
0
048h
01
11
Turns right
0
0
0
1
1
009h
10
00
Turns right
0
0
0
0
0
000h
10
01
Error
1
0
0
0
1
041h
10
10
No rotation
0
0
0
1
0
008h
10
11
Turns left
0
0
0
1
1
009h
11
00
Error
1
0
0
0
0
040h
11
01
Turns left
0
0
0
0
1
001h
11
10
Turns right
0
0
0
1
0
008h
11
11
No rotation
0
0
0
1
1
009h