ESI Registers
1016
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Extended Scan Interface (ESI)
37.3.24 Extended Scan Interface Processing State Machine Table Entry (ESI Memory)
Extended Scan Interface Processing State Machine Table Entry (ESI Memory)
Figure 37-45. Extended Scan Interface Processing State Machine Table Entry Register
7
6
5
4
3
2
1
0
Q7
Q6
Q5
Q4
Q3
Q2
Q1
Q0
Table 37-34. Extended Scan Interface Processing State Machine Table Entry Description
Bit
Field
Type
Reset
Description
7
Q7
When Q7 = 1, ESIIFG6 will be set. When ESIQ6EN = 1 and ESIQ7EN = 1 and
Q7 = 1, the PSM proceeds to the next state immediately, regardless of the
ESISTOP(tsm) signal and Q7 is used in the next-state calculation.
6
Q6
When Q6 = 1, ESIIFG5 will be set. When ESIQ6EN = 1, Q6 will be used in the
next-state calculation.
5
Q5
Bit 5 of the next state
4
Q4
Bit 4 of the next state
3
Q3
Bit 3 of the next state
2
Q2
When Q2 = 1, ESICNT1 decrements if ESICNT1EN = 1 and ESICNT2
decrements if ESICNT2EN = 1.
1
Q1
When Q1 = 1, ESICNT1 increments if ESICNT1EN = 1 and ESICNT0 increments
if ESICNT0EN = 1.
0
Q0
When ESIV2SEL=0 the PPUS3 signal is used as bit 2 (V2) for the next state. For
the case ESIV2SEL=1 the Q0 bit is used.