SAPH and SAPH_A Registers
552
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Sequencer for Acquisition, Programmable Pulse Generator, and Physical
Interface (SAPH, SAPH_A)
Table 21-36. SAPHASCTL0/SAPH_AASCTL0 Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
4
ASQCHSEL
R/W
0h
This bit selects the channel to start with when ASQ contols the
measuremnet sequences.
Reset type: PUC
0h (R/W) = CH0 is selected to start with.
If SAPHASCTL0.PNGCNT = 3 and SAPHASCTL1.CHTOG =1, then
the channel selection would be CH0 -> CH1 -> CH0 -> CH1.
If SAPHASCTL0.PNGCNT = 3 and SAPHASCTL1.CHTOG =0, then
the channel selection would be CH0 -> CH0 -> CH0 -> CH0.
1h (R/W) = CH1 is selected to start with.
If SAPHASCTL0.PNGCNT = 3 and SAPHASCTL1.CHTOG =0, then
the channel selection would be CH1 -> CH1 -> CH1 -> CH1.
If SAPHASCTL0.PNGCNT = 3 and SAPHASCTL1.CHTOG =1, then
the channel selection would be CH1 -> CH0 -> CH1 -> CH0.
3-2
RESERVED
R/W
0h
1-0
PNGCNT
R/W
0h
The total number of measurements to be performed.
0 = 1 measurement will be performed (Min)
1 = 2 measurements will be performed
2 = 3 measurements will be performed
3 = 4 measurements will be performed (Max)
Note: This bit field is static, does not reflect the currently reamining
measurement numbers.
Reset type: PUC