RTC_C Registers
761
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Real-Time Clock C (RTC_C)
29.4.42 RTCHOURBAKx Register – Hexadecimal Format
Real-Time Clock Hours Backup Register – Hexadecimal Format
(1)
These bits are not reset on POR.
Figure 29-45. RTCHOURBAKx Register
7
6
5
4
3
2
1
0
0
0
0
Hours
(1)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
Table 29-46. RTCHOURBAKx Register Description
Bit
Field
Type
Reset
Description
7-5
0
RW
0h
Always 0.
4-0
Hours
RW
0h
Hours. Valid values are 0 to 23.
29.4.43 RTCHOURBAKx Register – BCD Format
Real-Time Clock Hours Backup Register – BCD Format
(1)
These bits are not reset on POR.
Figure 29-46. RTCHOURBAKx Register
7
6
5
4
3
2
1
0
0
0
Hours – high digit
(1)
Hours – low digit
(1)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
Table 29-47. RTCHOURBAKx Register Description
Bit
Field
Type
Reset
Description
7-6
0
RW
0h
Always 0.
5-4
Hours – high digit
RW
0h
Hours – high digit. Valid values are 0 to 2.
3-0
Hours – low digit
RW
0h
Hours – low digit. Valid values are 0 to 9.