Addr.
Parameter
C
Setting Options
Default Setting
Voltage Control
_:15601:164
90V V.contr.3w:Number
of target voltage
•
1
•
2
•
3
•
4
1
_:15601:112
90V V.contr.3w:Target
voltage 1 w1
10.000 V to 340.000 V
110.000 V
_:15601:165
90V V.contr.3w:Target
voltage 2 w1
10.000 V to 340.000 V
110.000 V
_:15601:166
90V V.contr.3w:Target
voltage 3 w1
10.000 V to 340.000 V
110.000 V
_:15601:167
90V V.contr.3w:Target
voltage 4 w1
10.000 V to 340.000 V
110.000 V
_:15601:146
90V V.contr.3w:Target
voltage 1 w2
10.000 V to 340.000 V
110.000 V
_:15601:168
90V V.contr.3w:Target
voltage 2 w2
10.000 V to 340.000 V
110.000 V
_:15601:169
90V V.contr.3w:Target
voltage 3 w2
10.000 V to 340.000 V
110.000 V
_:15601:170
90V V.contr.3w:Target
voltage 4 w2
10.000 V to 340.000 V
110.000 V
_:15601:113
90V V.contr.3w:Band-
width
0.2 % to 10.0 %
1.0 %
_:15601:114
90V V.contr.3w:T1 char-
acteristic
•
Linear
•
Inverse
Linear
_:15601:115
90V V.contr.3w:T1 delay
5 s to 600 s
40 s
_:15601:116
90V V.contr.3w:T1
Inverse Min
5 s to 100 s
5 s
_:15601:117
90V V.contr.3w:T2 delay
0 s to 100 s
5 s
_:15601:118
90V V.contr.3w:Fast step
up
•
off
•
on
off
_:15601:119
90V V.contr.3w:Fast step
up limit
-50.0 % to 0.0 %
-6.0 %
_:15601:120
90V V.contr.3w:Fast step
up T delay
0.0 s to 10.0 s
2.0 s
_:15601:121
90V V.contr.3w:Fast step
down
•
off
•
on
on
_:15601:122
90V V.contr.3w:Fast step
down limit
0.0 % to 50.0 %
6.0 %
_:15601:123
90V V.contr.3w:Fast step
down T delay
0.0 s to 10.0 s
0.0 s
_:15601:124
90V V.contr.3w:Function
monitoring
0 min to 120 min
15 min
_:15601:162
90V V.contr.3w:Power-
flow supervision
•
off
•
on
on
_:15601:163
90V V.contr.3w:Regulate
with T2 at start
•
off
•
on
on
_:15601:171
90V V.contr.3w:Set
point mode active
•
off
•
on
on
Control Functions
8.9 Voltage Controller
1226
SIPROTEC 5, Overcurrent Protection, Manual
C53000-G5040-C017-8, Edition 07.2017
Summary of Contents for 7SJ82
Page 8: ...8 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 38: ...38 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 60: ...60 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 186: ...186 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 194: ...194 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 966: ...966 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1072: ...1072 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1236: ...1236 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1306: ...1306 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1370: ...1370 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1404: ...1404 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1576: ...1576 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1614: ...1614 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...
Page 1634: ...1634 SIPROTEC 5 Overcurrent Protection Manual C53000 G5040 C017 8 Edition 07 2017 ...