FSE CALCulate Subsystem
1065.6016.12
6.25
E-16
:CALCulate<1|2>:LIMit<1 to 8>:UPPer:MODE RELative | ABSolute
This command selects the relative or absolute scaling for the Y-axis of the selected upper limit line.
Example:
":CALC:LIM:UPP:MODE REL"
Features:
*RST value:
ABSolute
SCPI:
device-specific
Modes:
A, VA, BTS, MS
:CALCulate<1|2>:LIMit<1 to 8>:UPPer:SHIFt <numeric_value>
This command shifts a limit line, which has relative values for the Y-axis (levels or linear units such
as volt).
Example:
":CALC:LIM:UPP:SHIF 20dB"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
A, VA, BTS, MS
This command is an event which is why it is not assigned an *RST value and has no query.
:CALCulate<1|2>:LIMit<1 to 8>:UPPer:SPACing LINear | LOGarithmic
This command makes a selection between linear and logarithmic interpolation for the upper limit line.
Example:
":CALC:LIM:UPP:SPAC LIN"
Features:
*RST value:
LIN
SCPI:
device-specific
Modes:
A, VA, BTS, MS
:CALCulate<1|2>:LIMit<1 to 8>:LOWer[:DATA] <numeric_value>,<numeric_value>..
This command defines the values for the selected lower limit line.
Example:
":CALC:LIM:LOW -30,-40,-40,-30"
Features:
*RST value:
- (LIMit:STATe is set to OFF)
SCPI:
conforming
Modes:
A, VA, BTS, MS
The number of values for the CONTrol axis and the corresponding LOWer limit line have to be
identical.If the measured values violate the LOWer limit line, the limit check signals errors.
The unit must be identical with the unit selected by command
CALC:LIM:UNIT
.
The units DEG, RAD, S, and HZ are available in the vector signal analysis mode only.
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......