![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 293](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758293.webp)
TRIGger Subsystem FSE
1065.6016.12
6.236
E-16
:TRIGger<1|2>[:SEQuence]:LEVel[:EXTernal] –5.0 to +5.0V
This command sets the level of the external trigger source.
Example:
":TRIG:LEV 2V"
Features:
*RST value:
–5.0V
SCPI:
conforming
Modes:
A, VA, BTS, MS
:TRIGger<1|2>[:SEQuence]:LEVel:VIDeo 0 to 100PCT
This command sets the level of the video trigger source.
Example:
":TRIG:LEV:VID 50PCT"
Features:
*RST value:
50 PCT
SCPI:
device-specific
Modes:
A, VA, BTS, MS
:TRIGger<1|2>[:SEQuence]:LEVel:AF <numeric_value>
This command defines the level of the demodulated trigger source.
The ranges are:
AM-Demod
-120 to +120 PCT
FM-Demod
-1kHz to +1 kHz
PM-Demod
-12 .to.. +12 RAD
Example:
":TRIG:LEV:AF 50PCT"
Features:
*RST value:
0 PCT
SCPI:
device specific
Mode:
VA-A
:TRIGger<1|2>[:SEQuence]:HOLDoff -100s to 100s
This command defines the length of the trigger delay.
Example:
":TRIG:HOLD 500us"
Features:
*RST value:
0s
SCPI:
conforming
Modes:
A, VA
A negative delay time (pretrigger) can be set in the time domain (SPAN < 0 Hz) only. The maximum
permissible range and the maximum effective resolution of the pretrigger are limited by the set
sweep time (max range= - 499/500 x sweep time; max. resolution = sweep time/500). Pretriggering
is not possible when the rms or the average detector is activated.
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......