:READ:BURSt:POWer:LEVel?
This command increases the power control level for the measurement by one step, measures the
output power of the mobile and reads out the result.
Note that the command is no longer accepted after the measurement sequence is terminated which
implies that the power control level was read out again with
READ:BURSt:POWer:LEVel?
after the
maximum value was reached and marked with the ’FINISHED’ status.
Parameter:
The result is read out as an ASCII string in the following format:
<0>, <Power Ctrl Level>,<Rat-Level>,<Act-Level>, <Delta>,<Status>
<0>:
always 0
<Power Ctrl Level>:
current power control level
<Rat-Level>:
rated value for the current power control level acc.
to standard in dBm
<Act-Level>:
measured power in dBm
<Delta>:
difference between the measured power and the power
at the previous power control level.
<Status>:
result of the limit check in character data form:
PASSED
no limit exceeded
FAILED
limit exceeded
Example:
":READ:BURS:POW:LEV?"
Result:
0
,
3,35,32.5,5.6,FAILED
Features:
*RST value:
--
SCPI:
device-specific
Mode:
MS
The command
ABORt
terminates an ongoing measurement and resets the power control level to 0.
This command is only a query and therefore has no *RST value assigned. It is available only if
measurement of the maximum carrier power is selected. (see
:CONFigure:BURSt:POWer
).
:READ:BURSt:REFerence[:IMMediate]?
This command starts the premeasurement and as a result provides the measured level in dBm.
Example:
":READ:BURS:REF?
"
Feature:
*RST value:
--
SCPI:
device-specific
Mode:
MS, BTS
This is a query command only and therefore has no *RST value.
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......