![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 29](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758029.webp)
Structure and Syntax of the Device Messages
FSE
1065.6016.12
5.10
E-16
Device-specific commands
Hierarchy:
Device-specific commands are of hierarchical structure (see
Fig. 5-1). The different levels are represented by combined headers.
Headers of the highest level (root level) have only one key word. This
key word denotes a complete command system.
Example:
SENSe
This key word denotes the command system
SENSe
.
For commands of lower levels, the complete path has to be specified,
starting on the left with the highest level, the individual key words being
separated by a colon ":".
Example:
SENSe:FREQuency:SPAN:LINK STARt
This command lies in the fourth level of the SENSe system. It
determines which parameter remains unchanged when the span is
changed. If LINK is set to STARt, the values of CENTer and STOP are
adjusted when the span is changed.
SENSe
BANDwidth
FUNCtion
FREQuency
STOP
CENTer
SPAN
OFFSet
STARt
HOLD
LINK
DETector
Fig. 5-1 Tree structure the SCPI command systems using the SENSe system by way of example
Some key words occur in several levels within one command system. Their
effect depends on the structure of the command, that is to say, at which
position in the header of a command they are inserted.
Example:
SOURce:FM:POLarity NORMal
This command contains key word POLarity in the third
command level. It defines the polarity between modulator and
modulation signal.
SOURce:FM:EXTernal:POLarity NORMal
This command contains key word POLarity in the fourth
command level. It defines the polarity between modulation
voltage and the resulting direction of the modulation only for the
external signal source indicated.
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......