![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 400](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758400.webp)
FSE
Instrument Interfaces
1065.6016.12
8.7
E-15
DSR (Data Set Ready),
Input, active LOW,
Indicates that the remote station is ready to receive data.
RTS (Request To Send),
Output, active LOW.
Indicates that the local terminal wants to transmit data.
CTS (Clear To Send),
Input, active LOW.
Used to tell the local terminal that the remote station is ready to receive data.
RI (Ring Indicator),
Not used in FSE.
Interface Functions
For interface control, several strings are defined and control characters are reserved which are based
upon IEC-\IEEE bus control.
Table 8-4
Control strings or control characters of the RS-232 interface
Control string or character
Interface function
"@REM"
Switch over to remote
"@LOC"
Switch over to local
<Ctrl Q> 11 Hex
Enables character output
<Ctrl S> 13 Hex
Inhibits character output
0D Hex, 0A Hex
Terminator <CR>, <LF>
Transmission Parameters
To ensure error-free data transmission, the parameters of the instrument and the controller must have
the same settings. The parameters are defined in the SETUP-GENERAL SETUP menu.
Transmission rate
the following transmission rates can be set in the analyzer:
(baud rate)
110, 300, 600, 1200, 2400, 4800, 9600, 19200.
Data bits
Data transmission is in 7- or 8-bit ASCII code. The first bit
transmitted is the LSB (least significant bit).
Start bit
Each data byte starts with a start bit. The falling edge of the start
bit indicates the beginning of the data byte.
Parity bit
In order to detect errors, a parity bit may be transmitted. No
parity, even parity or odd parity may be selected. In addition, the
parity bit can be set to logic ’0’ or to logic ’1’.
Stop bits
The transmission of a data byte is terminated by 1, 1,5 or 2 stop bits.
Example:
Transmission of character ’A’ (41 hex) in 7-bit ASCII code,
with even parity and 2 stop bits:
01
02
03
04
05
06
07
08
09
10
11
Bit 01
Bit 02...08
Bit 09
Bit 10...11
Start bit
Data bits
Parity bit
Stop bits
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......