:CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:DDEMod:RESult?
MERM | MEPK | MEPS | PERM | PEPK | PEPS | EVRM | EVPK | EVPS | IQOF | IQIM | ADR | FERR |
FEPK | RHO| DEV | FSRM | FSPK | FSPS | DTTS
This command queries the error measurement results of digital demodulation.The results correspond
to the values obtained when the symbol table (SYMBOL TABLE/ ERRORS softkey) is selected in
manual operation. Marker values can be queried queried with command
CALCulate<1|2>:
MARKer<1...4>:Y?
and trace data with command
TRACe[:DATA].
Example:
":CALC:MARK:FUNC:DDEM:RES? EVRM"
Features:
*RST value:
-
SCPI:
device-specific
Mode:
VA-D
MERM
magnitude error in %rms
FERR frequency error in Hz
MEPK
maximum of magnitude error in %pk
FEPK
maximum of frequency error
MEPS
symbol number by which the maximum
in Hz
of the magnitude error occurred
ADR
amplitude drop in dB/symbol
PERM
phase error in deg
RHO
Rho-Factor
PEPK
maximum of phase error in deg
DEV
FSK deviation in Hz
PEPS
symbol number by which the maximum
of the phase error occurred
EVRM
vector error in %rms
FSPK
maximum of FSK deviation error
EVPK
maximum of vector error in %pk
in Hz
EVPS
symbol number by which the maximum
FSRM FSK deviation error in Hz
of the vector error occurred
FSPS
symbol number by which the
maximum of error occurred
IQOF
I/Q-offset error in %
DTTS trigger delay of synchronization
IQIM
I/Q Imbalance in %
This command is only a query which is why it is not assigned an *RST value.
:CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:POWer:SELect ACPower | CPOWer | OBANdwidth |
OBWidth | CN | CN0
This command selects the type of power measurement without modifying other settings.
Example:
":CALC:MARK:FUNC:POW:SEL ACP"
Features:
*RST value:
-
SCPI:
device-specific
Mode:
A-F
This command is an event which is why it is not assigned an *RST value.
ACPower
adjacent channel power measurement
CPOWer
channel power measurement
OBANdwidth | OBWidth
occupied bandwidth power measurement
CN
signal / noise power measurement
CN0
signal-/ noise power measurement based on 1Hz bandwidth
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......