![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 226](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758226.webp)
FSE SENSe Subsystem
1065.6016.12
6.169
E-16
:[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo 1Hz to 10MHz
This command defines the instrument’s video bandwidth.
Example:
":BAND:VID 10kHz"
Features:
*RST value:
- (AUTO is set to ON)
SCPI:
conforming
Mode:
A
The values for the video bandwidth are rounded in 1 | 2 | 3 | 5 steps.
:[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo:AUTO ON | OFF
This command either automatically couples the instrument’s video bandwidth to the resolution
bandwidth or cancels the coupling.
Example:
":BAND:VID:AUTO OFF"
Features:
*RST value:
ON
SCPI:
conforming
Mode:
A
:[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo:RATIO 0.001to 1000 | SINe | PULSe | NOISe
This command defines the ratio video bandwidth (Hz) / resolution bandwidth (Hz).
Parameter:
The parameters SINe, PULSe and NOISe may be used as synonyms for the
following values:
SINe:
1
PULSe: 10
NOISe:
0.1
Example:
":BAND:VID:RAT 10"
Features:
*RST value:
- (AUTO is set to ON)
SCPI:
conforming
Modes:
A, VA
The ratio to be entered is reciprocal to the ratio RBW/VBW used in manual control.
:[SENSe<1|2>:]BANDwidth|BWIDth:DEMod
5kHz to 200kHz (Real Time on) | 5kHz to 5MHz (Real Time off)
This command defines the demodulation bandwidth of the instrument for analog demodulation.
Example:
":BAND:DEM 100KHZ"
Features:
*RST value:
100KHZ
SCPI:
device-specific
Mode:
VA-A
The values for the demodulation bandwidth are rounded in steps of 1 | 2 | 3 | 5.
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......