![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 123](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758123.webp)
CONFigure-Subsystem FSE
1065.6016.12
6.66
E-16
:CONFigure[:BTS]:MEASurement?
This command queries which measurement is currently set.
PFERror
Phase-/Frequency Error
MACCuracy
Modulation Accuracy
POWer
Carrier Power
PTEMplate
Power v. Time
MODulation
Modulation Spectrum
SWITching
Transient Spectrum
SPURious
Spurious
Example:
":CONF:MEAS?"
Answer:
"PFER"
Features:
*RST-value: -
SCPI:
device-specific
Mode:
BTS
This command is a query and has therefore no *RST value assigned.
:CONFigure[:BTS]:ARFCn <numeric_value>
This command selects the number of the transmission channel of the base station.
Parameter:
<numeric_value>::=
1 to 124
(P-GSM phase I/II)
0 to 124, 975 to 1023
(E-GSM)
0 to 124, 955 to 1023
(R-GSM)
512 to 885
(DCS1800 phase I/II/II+)
512 to 810
(PCS1900)
128 to 251
(GSM850)
Example:
":CONF:ARFC 67
"
Features:
*RST value:
1
(P-GSM phase I/II)
0
(E-GSM; R-GSM)
512
(DCS1800 phase I/II/II+)
512
(PCS1900)
128
(GSM850)
SCPI:
device-specific
Mode:
BTS
:CONFigure[:BTS]:ARFCn:AUTO ONCE
This command is used to search for the channel number of the transmission channel of the base
station automatically. This requires only one channel to be active.
Example:
":CONF:ARFC:AUTO ONCE
"
Features:
*RST value:
--
SCPI:
device-specific
Mode:
BTS
This command is an event and thus has no query and no *RST value assigned.
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......