![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 132](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758132.webp)
FSE CONFigure-Subsystem
1065.6016.12
6.75
E-16
:CONFigure:BURSt:POWer[:IMMediate]
This command selects measurement of the average carrier power of the base station or mobile.
Example:
":CONF:BURS:POW"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
This command is an event and thus has no query and no *RST value assigned.
:CONFigure:BURSt:POWer:COUNt 1 to 1000
This command sets the number of bursts used for the determination of measured values.
Example:
":CONF:BURS:POW:COUN 100"
Features:
*RST value:
500 (GSM/DCS1800 phase I)
200 otherwise
SCPI:
device-specific
Modes:
BTS, MS
:CONFigure:BURSt:POWer:CONDition NORMal | EXTReme
This command defines the conditions for power measurement.
Example:
":CONF:BURS:POW:COND EXTR"
Features:
*RST value:
NORMal
SCPI:
device-specific
Modes:
BTS, MS
:CONFigure:BURSt:PTEMplate[:IMMediate]
This command selects measurement of power of the base station or mobile vs. time.
Example:
":CONF:BURS:PTEM"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
This command is an event and thus has no query and no *RST value assigned.
:CONFigure:BURSt:PTEMPlate:COUNt 1 to 1000
This command defines the number of bursts used for determining the measured value.
Example:
":CONF:BURS:PTEM:COUN 100"
Features:
*RST value:
500 (GSM/DCS1800 phase I)
200 otherwise
SCPI:
device-specific
Modes:
BTS, MS
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......