![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 204](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758204.webp)
FSE READ-Subsystem
1065.6016.12
6.147
E-16
:READ:BURSt:PERRor:RMS:MAXimum?
This command starts the measurement of the phase and frequency error of the base station or
mobile and reads out the maximum of the RMS-measurement of the phase error for the selected
number of bursts.
Example:
":READ:BURS:PERR:RMS:MAX?"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
When the measurement is started the instrument automatically assumes the SINGLE mode.
An ongoing measurement can be aborted via the command
ABORt
. Further results of the
phase/frequency error measurement can be then queried without restart of the measurement via the
:FETCh:BURSt
-subsystem.
This command is a query only and therefore has no *RST value assigned. It is available only if
measurement of the phase/frequency error is selected (see
:CONFigure:BURSt:PFERror
).
:READ:BURSt:PERRor:PEAK:STATus?
This command starts the measurement of the phase and frequency error of the base station or
mobile and reads out the status of the peak measurement of the phase error taken over the selected
number of bursts.
0: failed, 1: passed
Example:
":READ:BURS:PERR:PEAK:STAT?"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
When the measurement is started the instrument automatically assumes the SINGLE mode.
An ongoing measurement can be aborted via the command
ABORt
. Further results of the
phase/frequency error measurement can be then queried without restart of the measurement via the
:FETCh:BURSt
-subsystem.
This command is a query only and therefore has no *RST value assigned. It is available only if
measurement of the phase/frequency error is selected (see
:CONFigure:BURSt:PFERror
).
:READ:BURSt:PERRor:PEAK:AVERage?
This command starts the measurement of the phase and frequency error of the base station or
mobile and reads out the maximum of the peak measurement of the phase error taken over the
selected number of bursts.
Example:
":READ:BURS:PERR:PEAK:AVER?"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
When the measurement is started the instrument automatically assumes the SINGLE mode.
An ongoing measurement can be aborted via the command
ABORt
. Further results of the
phase/frequency error measurement can be then queried without restart of the measurement via the
:FETCh:BURSt
-subsystem.
This command is a query only and therefore has no *RST value assigned. It is available only if
measurement of the phase/frequency error is selected (see
:CONFigure:BURSt:PFERror
).
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......