![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 142](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758142.webp)
FSE CONFigure-Subsystem
1065.6016.12
6.85
E-16
CONFigure:SPECtrum Subsystem
This subsystem provides the commands for configuring the measurements in the GSM BTS Analyzer
mode (FSE-K11) or in the GSM MS Analyzer mode (FSE-K10) used to determine the power of the
spectral contributions due to modulation and switching (modulation spectrum, transient spectrum).
COMMAND
PARAMETERS
UNIT
COMMENT
CONFigure
:SPECtrum
:MODulation
[:IMMediate]
:COUNt
:RANGe
:TGATe
:SWITching
[:IMMediate]
:COUNt
--
<numeric_value>
ARFCn | TXBand | RXBand |
COMBined | DCSRx1800 |
G8Rxband | PCSRx1900
<Boolean>
--
<numeric_value>
--
--
--
--
no query, Option FSE-K11 or FSE-K10
Option FSE-K11 or FSE-K10
Option FSE-K11 or FSE-K10
Option FSE-K11
Option FSE-K11 or FSE-K10
no query
:CONFigure:SPECtrum:MODulation[:IMMediate]
This command selects measurement of the spectrum due to modulation.
Example:
":CONF:SPEC:MOD"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
This command is an event and has thus no query and no *RST value assigned.
:CONFigure:SPECtrum:MODulation:COUNt 1 to 1000
This command sets the number of bursts used for determining the average and maximum values.
Example:
":CONF:SPEC:MOD:COUN 100"
Features:
*RST value:
500 (GSM/DCS1800 phase I)
200 otherwise
SCPI:
device-specific
Modes:
BTS, MS
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......