![Rohde & Schwarz 1065.6000.20 Operating Manual Download Page 298](http://html1.mh-extra.com/html/rohde-and-schwarz/1065-6000-20/1065-6000-20_operating-manual_1477758298.webp)
FSE
Alphabetical List of Commands
1065.6016.12
6.241
E-16
Alphabetical List of Commands
In the following, all remote-control commands are listed with their parameters and page numbers.
Generally, they are arranged alphabetically according to the keywords of the command.
Command
Parameter
Page
:ABORt
6.8
:CALCulate<1|2>:CTHReshold
MIN to MAX
(depending on current unit)
6.16
:CALCulate<1|2>:CTHReshold:STATe
ON | OFF
6.16
:CALCulate<1|2>:DELTamarker<1 to 4>:AOFF
6.10
:CALCulate<1|2>:DELTamarker<1 to 4>:FUNCtion:FIXed:RPOint:X
<numeric_value>
6.13
:CALCulate<1|2>:DELTamarker<1 to 4>:FUNCtion:FIXed:RPOint:Y
6.13
:CALCulate<1|2>:DELTamarker<1 to 4>:FUNCtion:FIXed:RPOint:Y:OFFSet
<numeric_value>
6.13
:CALCulate<1|2>:DELTamarker<1 to 4>:FUNCtion:FIXed[:STATe]
ON | OFF
6.13
:CALCulate<1|2>:DELTamarker<1 to 4>:FUNCtion:PNOise:RESult?
6.14
:CALCulate<1|2>:DELTamarker<1 to 4>:FUNCtion:PNOise[:STATe]
ON | OFF
6.13
:CALCulate<1|2>:DELTamarker<1 to 4>:MAXimum:APEak
6.11
:CALCulate<1|2>:DELTamarker<1 to 4>:MAXimum:LEFT
6.12
:CALCulate<1|2>:DELTamarker<1 to 4>:MAXimum:NEXT
6.11
:CALCulate<1|2>:DELTamarker<1 to 4>:MAXimum:RIGHt
6.11
:CALCulate<1|2>:DELTamarker<1 to 4>:MAXimum[:PEAK]
6.11
:CALCulate<1|2>:DELTamarker<1 to 4>:MINimum:LEFT
6.12
:CALCulate<1|2>:DELTamarker<1 to 4>:MINimum:NEXT
6.12
:CALCulate<1|2>:DELTamarker<1 to 4>:MINimum:RIGHt
6.12
:CALCulate<1|2>:DELTamarker<1 to 4>:MINimum[:PEAK]
6.12
:CALCulate<1|2>:DELTamarker<1 to 4>:MODE
ABSolute | RELative
6.10
:CALCulate<1|2>:DELTamarker<1 to 4>[:STATe]
ON | OFF
6.9
:CALCulate<1|2>:DELTamarker<1 to 4>:STEP:AUTO
ON | OFF
6.14
:CALCulate<1|2>:DELTamarker<1 to 4>:STEP[:INCRement)]
<numeric value>
6.14
:CALCulate<1|2>:DELTamarker<1 to 4>:TRACe
1 to 4
6.10
:CALCulate<1|2>:DELTamarker<1 to 4>:X
0 to MAX
(frequency | sweep time | symbols)
6.10
:CALCulate<1|2>:DELTamarker<1 to 4>:X:RELative?
6.10
:CALCulate<1|2>:DELTamarker<1 to 4>:Y?
6.11
:CALCulate<1|2>:DLINe<1|2>
MINimum to MAXimum
(depending on current unit)
6.15
:CALCulate<1|2>:DLINe<1|2>:STATe
ON | OFF
6.15
:CALCulate<1|2>:FEED
‘XTIM:DDEM:MEAS’ |
‘XTIM:DDEM:REF’ |
‘XTIM:DDEM:ERR:MPH’ |
‘XTIM:DDEM:ERR:VECT’ |
‘XTIM:DDEM:SYMB’ | 'XTIM:AM' |
'XTIM:FM' | 'XTIM:PM' |
'XTIM:AMSummary' |
'XTIM:FMSummary' |
'XTIM:PMSummary' | ‘TCAP’’
6.18
:CALCulate<1|2>:FLINe<1|2>
0 GHz to fmax
6.17
:CALCulate<1|2>:FLINe<1|2>:STATe
ON | OFF
6.17
Summary of Contents for 1065.6000.20
Page 3: ......
Page 5: ......
Page 17: ......
Page 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Page 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Page 391: ......
Page 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Page 419: ......
Page 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Page 429: ......