Section 12 Timer Unit (TMU)
Rev. 5.00 May 29, 2006 page 334 of 698
REJ09B0146-0500
Auto-reload count operation
Figure 12.3 shows the TCNT auto-reload operation.
TCNT value
TCOR
H'00000000
STR0 to STR2
UNF
TCOR value set to
TCNT during underflow
Time
Figure 12.3 Auto-Reload Count Operation
TCNT count timing
1. Internal Clock Operation: Set the TPSC2 to TPSC0 bits in TCR to select whether peripheral
module clock P
φ
or one of the four internal clocks created by dividing it is used (P
φ
/4, P
φ
/16,
P
φ
/64, P
φ
/256). Figure 12.4 shows the timing.
P
φ
Internal
clock
Timer counter
input clock
TCNT
N + 1
N
N – 1
Figure 12.4 Count Timing when Internal Clock Is Operating
Summary of Contents for SH7706 Series
Page 8: ...Rev 5 00 May 29 2006 page viii of xlviii ...
Page 160: ...Section 5 Cache Rev 5 00 May 29 2006 page 112 of 698 REJ09B0146 0500 ...
Page 370: ...Section 11 Watchdog Timer WDT Rev 5 00 May 29 2006 page 322 of 698 REJ09B0146 0500 ...
Page 554: ...Section 17 Pin Function Controller PFC Rev 5 00 May 29 2006 page 506 of 698 REJ09B0146 0500 ...
Page 576: ...Section 18 I O Ports Rev 5 00 May 29 2006 page 528 of 698 REJ09B0146 0500 ...
Page 746: ...Index Rev 5 00 May 29 2006 page 698 of 698 REJ09B0146 0500 ...
Page 749: ...SH7706 Group Hardware Manual ...