12 - 37
12 Troubleshooting
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
12-
5 T
rou
blesh
oo
ting
12
12-
5-2
T
rou
bleshooting Using AL S
tatus C
odes
0050
ESC Error
An error occurred in the
EtherCAT slave communi-
cations controller.
Error access from the
non-OMRON EtherCAT
master
Please contact the manufacturer of
EtherCAT master.
0051
Error of the EtherCAT
slave communications
controller or false detec-
tion
If this event occurs repeatedly after
you cycled the power supply, the
EtherCAT slave communications
controller is faulty. Replace the
Servo Drive.
0061
Node Address
Updated
The node address is changed to a value of the ID
switches.
Check the node address value.
Set a correct value if it is wrong.
The node address is changed from a set value in Sys-
mac Studio to a value of the ID switches.
8000
Unit Restarted Restart was performed.
---
AL status
code (hex)
Name
Cause
Measures