Appendices
A - 136
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Event name
Electronic Gear Setting Error
Event code
387F0000 hex
Description
The electronic gear ratio exceeded the allowable range.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
At power ON
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling
slave power)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
The electronic gear ratio
exceeded the allowable range
Correct the electronic gear ratio to
the range from 1/2,000 to 2,000
times.
Set the electronic gear ratio to the
range from 1/2,000 to 2,000 times.
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: 9300 hex
Event name
Servo Drive Overheat
Event code
38800000 hex
Meaning
The internal temperature of Servo Drive exceeded the circuit protection level.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Error reset
(after resetting
slave errors)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
The ambient temperature of the
Servo Drive exceeded the speci-
fied value
Improve the ambient temperature
and the cooling conditions of the
Servo Drive.
Check the ambient temperature of
the Servo Drive and set up the
necessary cooling conditions.
Overload
Increase the setting of the acceler-
ation/deceleration time or stop-
ping time to lighten the load. Or,
increase the capacities of the
Servo Drive and the motor.
Increase the setting of the acceler-
ation/deceleration time or stop-
ping time as much as possible to
lighten the load.
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: 1500 hex
Summary of Contents for R88D-1SN01H-ECT